PWM frequency
This setting lets you select between different LED PWM frequencies for different
applications and adjust frequencies to give the best results at different camera shutter
frequencies. Changing the PWM frequency can improve dimming performance or
help avoid flicker and beat frequencies in video images.
The following PWM settings are available:
● Low – PWM frequency is fixed at a lower level, giving best dimming results.
● Optimum (default) – PWM frequency is set to a level which offers a good
compromise between best dimming results and avoiding flicker.
● High1 – PWM frequency is set to a higher level.
● High2 – PWM frequency is set to a higher level than High 1.
● Max – PWM frequency is set to the highest possible level. Use this setting for slow
motion video or high speed camera applications. Dimming resolution at this setting
is not as good as the other PWM settings.
Note: A higher PWM frequency may affect dimming performance. The PWM
frequency setting is stored in the fixture and is not affected by cycling power off and
on. However, it will be affected if you use the Factory Defaults command in the control
menus. As a rule, you should set all the fixtures in an installation to the same PWM
frequency in order to ensure the same performance.
Pixel mirror
The Pixel mirror setting lets you flip the fixture’s pixel layout:
● Off gives the standard pixel layout (see ‘Pixel layout’ on page 38). Pixel 01 is at the
Power and DMX THRU connectors end of the fixture and pixel 18 is at the Power and
DMX IN connectors end of the fixture.
● y-mirror flips the pixel layout over the y-axis. Pixel 18 is at the Power and DMX THRU
connectors end of the fixture and pixel 01 is at the Power and DMX IN connectors
end of the fixture.
No signal
The No signal settings let you manage how the fixture behaves if no DMX signal is
present (if the fixture is being controlled by DMX but the DMX signal stops, or if you
apply power to the fixture when no DMX signal is present):
● Blackout sets the fixture to black out whenever it is not receiving a DMX signal. This is
the default setting.
● Hold sets the fixture to continue using the last DMX values it received.
● Scene (Stand-alone) sets the fixture to play its stored stand-alone scene (see
Capture DMX Values below) when the fixture is not receiving a DMX signal. If no
stand-alone scene is stored in memory, the fixture will black out.