Note: When changing from ON back to OFF to re-enable tilt movement, you must
carry out a reset before you can operate tilt normally.
Display Mode
Gives different behavior options for the display in the fixture’s control panel. This can
be helpful in case of errors or during service operations. Three settings are available:
Auto (default): the display automatically switches off after a few seconds if the
fixture is receiving a valid control signal and has not detected an error. If the fixture
is not receiving a valid control signal, the display will flash. If the fixture has
detected an error, the display remains constantly on and shows the error.
On: The display stays on constantly. This setting can be useful if you are configuring
or servicing the fixture.
Off: The display will automatically switch off after a few seconds even if the fixture is
not receiving a valid control signal or if it has detected an error. Pressing any button
turns on the display again.
Display Orientation
Lets you select Normal, Upside-down or Auto control panel display orientation.
If Display Orientation is set to Auto, changing the display orientation by pressing UP and
DOWN at the same time will only change the display orientation until the next power
cycle.
Hibernation
Lets you put the fixture into energy-saving mode and disables all electronic
components apart from the DMX receiving module.
You can take the fixture out of hibernation mode with a power off/on cycle, via RDM
or using the Special / Control DMX channel. If you do this, the fixture will perform a
fixture reset before returning to normal operation.
Load User Settings
Lets you load different custom fixture configurations or return the fixture to the default
fixture settings.
To save a custom setting preset from 1 to 3, see Service
Advanced
Save_Settings.
Load User Settings 1 to 3 loads one of three specific custom fixture settings. You
must confirm the function for 3 seconds before the new settings are loaded (see
Fixture Settings
Load User Settings).
Save User Settings 1 to 3 saves the current fixture settings as a set of user settings.
You must confirm the function for 2 seconds in order to save the settings as one of
the three custom settings presets (see Service
Advanced
Save User Settings).