6 impression® FR1 User Manual
- EU power cable: 16 A, 1.5 mm², H05VV-F, 1.5 m
Do not connect more than sixteen (16) impression FR1 fixtures to power in a chain at
100-120 V, 60 Hz.
Do not connect more than thirty-two (32) impression FR1 fixtures to power in a chain
at 200-240 V, 50 Hz.
The voltage and frequency at the Mains Out socket are the same as the voltage and
frequency applied to the Mains In socket. Only connect devices to the Mains Out
socket that accept this voltage and frequency.
If a fuse blows, replace it with one of the original type and rating only. If new fuses
blow, disconnect the product from power and send it to a technician authorized by
GLP for repair.
Fire safety and protection from burns
Do not operate the product if the ambient temperature (Ta) exceeds 45° C (115° F).
The surface of the product’s casing can reach up to 55° C (131° F) during operation.
Avoid contact by persons and materials. Do not install the product in a location
where there is a risk of accidental contact. Allow the product to cool for at least 10
minutes before handling
Keep the product well away from flammable materials.
Keep all combustible materials (e.g. fabric, wood, paper) at least 100 mm (4 in.)
away from the product.
Ensure that there is free and unobstructed airflow around the product. Provide a
minimum clearance of 100 mm (4 in.) around fans and air vents.
Do not illuminate surfaces within 500 mm (19.7 in.) of the product.
Do not install a fuse that has a higher rating than the one originally installed in the
product. Do not bypass fuses.
Do not stick filters, masks or other materials onto optical components.
The product’s optical components can focus the sun’s rays, creating a risk of fire and
damage. Do not expose the front of the product to sunlight or any other intense light
source, even from an angle.
Eye safety
The impression FR1 is classified as a Risk Group 2 product according to EN 62471.
Possibly hazardous radiation emitted.