Note that in multicast mode, the Operation Modes for both Sender and Receiver units are
automatically set to Active per request mode.
Under Active per request mode, multiple USB devices may be present on one or more
Receiver units. However, only one Receiver unit can have USB control at a time.
By default, the rst Receiver unit connected to the system will have USB control.
In the example below, Receiver unit R2 currently has control (we arbitrarily connected
Receiver unit R2 before Receiver unit R1).
R
2
S
1
IN
S
2
IN
S
3
IN
OUT
USB
CABLE
R
1
07 07
05 07 09
OUT
Important: If switching between Active per request mode and Active on link mode, the
Apply and Reboot buttons must be clicked to apply changes.
USB Control