STEP 3 INSTALL ADAPTER PLATE
• Install an adapter
plate over the
mounting plate on
the plenum with the
flange towards the
outside. Use 4
screws provided.
STEP 5 INSTALL ADAPTER PLATE,
HANGER BRACKETS
• Place the other adapter plate
over the 4 studs on the motor
with the flange facing outwards.
• Place hanger brackets over the
blower studs and secure with
nuts. One bracket in each
corner, as illustrated.
• Set the brackets to reach a
14-1/2” span between floor
joists, or adjust to mate with
the hole location in the floor
above.
• Secure the blower to the joists
with lag bolts provided.
STEP 4 CUT DUCTWORK HOLES
• Install the vent into the cabinet according to the
installation instructions packed with the vent.
• Place the 90° elbow over the adapter plate.
• Mark the location for a 6-1/2" round hole in the floor
of the cabinet.
NOTE: Check to be sure there is no interference
below the cabinet floor. The mounting plate on the
plenum can be shifted 3-1/2" to the left or right sides.
• The blower will fit between floor joists, 16” on
center. Or, provide a surface to attach the entire
assembly to the underside of the floor.
• Cut the hole through the cabinet and another hole
through the floor below.
Check for
Interference
Below Floor
90°
Elbow
Cut a
6-1/2" Dia.
Hole
STEP 6 CONNECT DUCTWORK
• Install a section of 6" round duct through the cabinet
floor and over the adapter plate on the motor. Tape
to seal the joint.
• Connect the plenum to the ductwork with 90° elbow.
• Install 3-1/4" x 10" duct to the blower outlet to reach
the outside wall or roof cap.
90°
Elbow
6"
Round
Duct
• DO NOT USE flexible plastic ducting.
• Use the straightest duct run possible.
• For satisfactory performance the duct run should not
exceed 150 ft. Refer to the table of equivalent lengths.
• Install ductwork so the piece of duct nearest the
downdraft unit slots INTO the next piece of the duct.
Secure the joints with self-tapping screws and apply
duct tape around the joints to ensure an airtight seal.
Duct Tape
Over Seam and Screw
Screw
Air
Flow
Install Adapter
Plate
Bekijk gratis de handleiding van GE JXRB67, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
Merk | GE |
Model | JXRB67 |
Categorie | Niet gecategoriseerd |
Taal | Nederlands |
Grootte | 571 MB |