JXRB67 KIT
This kit provides for the installation of the blower and
motor outside of the cabinet, such as below the floor.
Use this kit for indoor remote installations only. It
must be installed in an accessible location.
STEP 1 PREPARE THE VENT
• Flatten the shipping box to use as a pad.
• Place the unit on its back and onto the protective
pad.
• Remove the 3 screws holding the control box on the
plenum. Retain screws.
• Cut the blower
leads approxi-
mately 3” from the
plug on the end of
the vent.
• Remove the blower
conduit by loosen-
ing the screw on the
fitting.
BEFORE YOU BEGIN
Read these instructions completely and carefully.
IMPORTANT - Save these instructions for local inspector’s use.
IMPORTANT - Observe All Governing Codes and Ordinances.
Note to Installer - Be sure to leave these instructions with the Consumer.
Note to Consumer - Keep these instructions for future reference.
Tools and Materials required:
• Chalk or Pencil
• Measuring tape
• Drill with appropriate bits
• 1/4", 3/8" and 7/16" Nut driver
• Junction box with cover (per local codes)
• Wire nuts
• Duct Tape
• Safety glasses
• 6" round 90° elbow
• 6" round duct, length to reach blower location
• 3-1/4" x 10" duct, sufficient length to reach the
outdoor wall cap or roof cap.
• Electrical cable and connectors, sufficient length to
connect the downdraft vent to the remote blower
location. 14-guage min. is recommended, must
conform to local codes.
Parts Supplied
Package
of Screws
8 Hanger
Brackets
2 Adapter
Plates
90°
Elbow
6"
Round
Duct
Blower/
Motor
Control Box
Mounting
Plate
STEP 2 REMOVE THE BLOWER
• Remove the 4 screws holding the blower to the
mounting plate. Retain all screws.
• Lift the blower off the assembly, turn it over to
access the 4 nuts holding the blower to the mounting
plate. Remove the nuts, lift the mounting plate off the
blower.
• Reinstall the mounting plate onto the plenum with
the 4 original screws.
IMPORTANT: Do not lift motor by power cable.
Damage will occur!
Control Box
Loosen
Screw
3"