Garrett Paragon handleiding
Handleiding
Je bekijkt pagina 34 van 44

34 1557900 REV B 1 Garrett Metal Detectors
8. OPERATION
8.1. Operational Testing
• Operational Test Piece
Actual forbidden objects should be used as
targets for initial calibration. Once the detector
settings are established it is recommended that a
test piece be selected which is similar in size, shape,
and metallic composition to the smallest forbidden
object. is test piece can be used to generally verify
operation on a regular basis without the necessity
of having actual weapons on-hand at the screening
station.
Garrett oers an optional Operational Test Piece
(OTP) that meets the specications established by
the U.S. Federal Aviation Administration (FAA)
and is a representation of a small handgun. Gar-
rett also oers an optional Flat Test Piece (FTP)
which represents a small knife. You may want to
consider other test pieces if your screening opera-
tion requires detection of objects other than guns
and / or knives.
8.2 Operator Responsibilities
e Operator must follow the Supervisor’s in-
structions regarding use of the Paragon and the
appropriate response to alarms.
e Operator’s ongoing responsibility is to
ensure that the Paragon always operates according
to the information displayed on the OLED Dis-
play (see Figure 4-1) and to determine the cause of
the alarms.
e Operator should ensure that the:
1. Paragon is always operating properly.
2. Program and sensitivity settings are correct
by pressing VIEW SETTING
3. LED bar graph shows minimal interference
(two lights maximum)
4. Green READY light is on
5. Operational testing is performed according
to the Supervisor’s instructions.
6. Volume set no higher than needed relative
to ambient noise.
• Ready Light
e Green READY light must appear before a
patron is permitted to enter the walk-through for
inspection.
If the READY light shuts o and remains
o, the Operator should activate the self test
report by pressing the OPERATE keypad; the
results will appear on the OLED Display. Dur-
ing this time, no one is permitted to enter the
walk-through. Trac may resume only when the
READY light reappears and remains on.
If the READY light does not reappear or a failure
message is displayed on the OLED Display, the
Operator should attempt to solve the problem or
consult the Supervisor.
• Diagnostic Problems
As a general rule, the operator should follow the
instructions regarding the appropriate response to
failures revealed by the self test. e operator may
be able to remedy the following failures:
• MOTION SENSOR FAIL: Ensure the open-
ings for the motion sensor located at mid height of
the B panel are not blocked.
• RX ZN # BAL FAIL: Ensure there is no large
metal object near the Paragon.
If the self-test reveals a failure that severely limits
or prohibits the Paragon’s performance, the alarm
will sound, the OLED Display will ash and the
message SYSTEM FAILURE will appear on the
OLED Display. e OLED will continue ash-
ing until the power is turned o or the failure is
remedied. e Operator should inform the Super-
visor of any problems that occur. Additional Diag-
nostic Info can be found in Table 9-1.
• Responding to Alarms
If a patron triggers an alarm and the alarm light
appears, the Operator should instruct the individ-
ual to step outside the walk-through and remove
any metal objects from their body and/or clothing.
e Operator should then either scan the patron
with a hand-held metal detector, such as a Super-
Scanner or SuperWand or ask the person to re-enter
the walk-through.
If an alarm sounds after the patron re-enters
the walk-through, he or she must be re-scanned
with a hand-held metal detector.
e pinpoint lights facilitate the screening
process by indicating the location of ALL alarm-
able objects within 66 zone areas. In cases, where
there is more than one object, the lights appear in
each array that requires investigation. is enables
the Operator to know from which area(s) objects
require removal and to concentrate on the problem
areas when hand scanning, resulting in improved
overall security and increased throughput.