Garrett Paragon handleiding
Handleiding
Je bekijkt pagina 33 van 44

1557900 REV B1 Paragon User Manual 33
7.4 CASE 4
Description: All detectors are Paragons connected to the same AC-Line Phase.
Distance to
Adjacent
Unit Sync Method
Detector
Location
Multi-
Unit
Role Frequency Channel Notes
• All units must be powered from the
same phase of AC power line, i.e.
daisy chain power cords or ensure
all outlets are connected to the same
breaker, or breakers are on the same
phase.
Any
Line Sync
Any Solo
Manually Set
Frequency to
LINE
Sequential:
Ch1, Ch2,
Ch1, Ch2…
Multiple Walk-Through Site Installation
Paragon
Role: Solo
Frequency: Line
Channel: 1
Paragon
Role: Solo
Frequency: Line
Channel: 2
Paragon
Role: Solo
Frequency: Line
Channel: 1
Paragon
Role: Solo
Frequency: Line
Channel: 2
Paragon
Role: Solo
Frequency: Line
Channel: 1
AC Power
Setting up Multiple Units using Line Sync
1. Begin with all units o.
2. Switch on one unit and login with admin access (ACCESS > 67890).
3. Press MENU
to "Multi-Unit Role" and set to "Solo" using + or - buttons.
4. Press MENU
to "Frequency:" and press + to alter the setting. Change the frequency by pressing + button until "Line" is
shown on the screen or by using the Scrollbar to slide right until "Line" is shown on the screen.
4. Press MENU
to "Channel:" and press + to alter the setting. Press + or - to change to channel 1.
Note: Additional units should be set in increasing numerical order from left to right and decreasing numerical order from
right to left to avoid channel interference.
5. Repeat steps 2-4 for additional units.
(>1") (>1") (>1") (>1")