Furuno VR-7000 handleiding
Handleiding
Je bekijkt pagina 56 van 79

3. TROUBLESHOOTING
3-6
412456, 1 CPU VCORE Voltage
Error (CPU Board
VCORE Voltage Er-
ror)
Voltage error on CPU board.
(VCORE line)
Restart VDR. To restart the
VDR, open the DCU door with
its key and turn on the AC and
BATTERY switches on the
power control panel, then turn
the switches on after shut-
down of the DCU. If the error
re-occurs, contact your deal-
er.
412457, 1 Low CPU Battery Volt-
age (CPU Board Bat-
tery Voltage Lower)
Voltage of battery on CPU
board is low.
412458, 1 Low CPU FAN Rota-
tion Speed
Rotation speed of CPU FAN is
low.
412459, 1 CPU FAN Not Rotated CPU FAN stopped.
412460, 1 Low External FAN1
Rotation Speed
Rotation speed of external
FAN1 is low.
412461, 1 External FAN1 Not
Rotated
External FAN1 stopped.
412462, 1 Low External FAN2
Rotation Speed
Rotation speed of external
FAN2 is low.
412463, 1 External FAN2 Not
Rotated
External FAN2 stopped.
412501, 1 No FixedDRU Con-
nection
Fixed DRU has been discon-
nected more than 600 seconds.
Check the connection with the
Fixed DRU. If OK, contact
your dealer.
412502, 1 No FloatDRU Con-
nection
Float-free DRU has been dis-
connected more than 600 sec-
onds.
Check that the capsule is
seated in the bracket correct-
ly. If OK, contact your dealer.
412503, 1 No LongTermDevice
Connection
Long Term Device has been
disconnected more than 600
seconds.
Contact your dealer.
412504, 1 No UserDisk Connec-
tion
UserDisk has been disconnect-
ed more than 600 seconds.
412514, 1 UserDisk Recording
Failure
UserDisk is unable to write. Restart the VDR. To restart
the VDR, open the DCU door
with its key and turn on the AC
and BATTERY switches on
the power control panel, then
turn the switches on after
shutdown of the DCU.
412515, 1 FixedDRU Exchanged Fixed DRU is replaced.
412516, 1 FloatDRU Exchanged Float-free DRU is replaced.
412517, 1 LongTermDevice
Exchanged
Long Term Device is replaced.
412518, 1 No.1 LongTermDe-
vice Error
No.1 Long Term Device is error.
412519, 1 No.2 LongTermDe-
vice Error
No.2 Long Term Device is error.
412521, 1 FixedDRU Memory
Shortage
Data cannot be recorded more
than 48 hours.
Contact your dealer.
412522, 1 FloatDRU Memory
Shortage
Data cannot be recorded more
than 48 hours.
412523, 1 LongTermDevice
Memory Shortage
• VR-7000: Data cannot be re-
corded more than “720 hours
+ used hours in SAVE ar-
eas”.
• VR-7000S: Data cannot be
recorded more than “48
hours + used hours in SAVE
areas”.
412524, 1 UserDisk Memory
Shortage
Data cannot be recorded more
than setting hours.
ID Title Description Action
Bekijk gratis de handleiding van Furuno VR-7000, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
Merk | Furuno |
Model | VR-7000 |
Categorie | Niet gecategoriseerd |
Taal | Nederlands |
Grootte | 11636 MB |