3. TROUBLESHOOTING
3-5
412181, 1 FixedDRU Setting De-
fect
Fixed DRU information is read,
even though settings are not
complete.
Contact your dealer.
412182, 1 FloatDRU Setting De-
fect
Float DRU information is read,
even though settings are not
complete.
412185, 1 SAVE Setting Differ-
ence
SAVE function settings differ
between VDR and RAP.
Confirm VDR and RAP set-
tings.
412186, RAP Version is old RAP/mod.tgz program version
is not compatible with the DCU
program version.
Contact your dealer.
412187, Module Version is old
412246, PDU Failure The cable between PDU and
CPU block is not connected.
412254, 1 Self Test Failure System failed by the self test.
412431, 1 Serial Buffer Overflow Serial data from DCU serial
channel (1 - 8 ch) are not re-
corded to Fixed DRU, Float-free
DRU and Long Term Device.
Restart VDR. To restart the
VDR, open the DCU door with
its key and turn on the AC and
BATTERY switches on the
power control panel, then turn
the switches on after shut-
down of the DCU. If the error
re-occurs, contact your deal-
er.
412432, 1 JB Buffer Overflow Serial, analog and digital data
from Junction Box (IF-8530) are
not recorded to Fixed DRU,
Float-free DRU and Long Term
Device.
412437, 1 Fatal System Failure Fatal system error. This indi-
cates that VDR can not be re-
booted automatically.
412438, 1 System Information
Error (VDR System In-
formation Error)
VDR system information can
not be acquired. Usually, this
error is recovered automatical-
ly.
If error is not recovered auto-
matically, restart VDR. To re-
start the VDR, open the DCU
door with its key and turn on
the AC and BATTERY switch-
es on the power control panel,
then turn the switches on after
shutdown of the DCU. If it
does not recover, contact your
dealer.
412451, 1 High CPU Core Tem-
perature
Temperature of CPU core is
high.
Restart VDR. To restart the
VDR, open the DCU door with
its key and turn on the AC and
BATTERY switches on the
power control panel, then turn
the switches on after shut-
down of the DCU. If the error
re-occurs, contact your deal-
er.
412452, 1 High CPU System
Temperature (CPU
Board System Tem-
perature High)
Temperature of CPU board is
high.
412453, 1 CPU +3.3V Voltage
Error (CPU Board
+3.3V Voltage Error)
Voltage error on CPU board.
(+3.3 V line)
412454, 1 CPU +5V Voltage Er-
ror (CPU Board +5V
Voltage Error)
Voltage error on CPU board.
(+5 V line)
412455, 1 CPU +12V Voltage Er-
ror (CPU Board +12V
Voltage Error)
Voltage error on CPU board.
(+12 V line)
ID Title Description Action