3. TROUBLESHOOTING
3-4
BAM mode indications
The following indications are shown in the BAM mode. The indications have no cate-
gory and priority, are not output as ALF sentences.
Note: Indications also appear on the alert list.
ID Title Description Action
412026, 1 GPS Large Time
Difference
This indicates that the time dif-
ference between the system
time of the DCU and the UTC
time supplied by a GPS receiv-
er is more than 10 seconds.
Restart the DCU with the GPS
receiver connected. To restart
the VDR, open the DCU door
with its key and turn on the AC
and BATTERY switches on
the power control panel, then
turn the switches on after
shutdown of the DCU. If the
error re-occurs, contact your
dealer.
412083, 1 No AMS1 Connection AMS1 is missing. Connection to
AMS1 is lost.
Check cable connected to
AMS1. Reconnect AMS1.
412085, 1 No AMS2 Connection AMS2 is missing. Connection to
AMS2 is lost.
Check cable connected to
AMS2. Reconnect AMS2.
412088, 1 No JB Connection Indicates that Junction Box (IF-
8530) is missing.
Check cable connected to
Junction Box. Reconnect
Junction Box. If the error re-
occurs, contact your dealer.
412170, 1 VDR Configuration
Failure
Data cannot be stored because
of abnormal VDR configuration.
Restore VDR config data. If
the error re-occurs, contact
your dealer.
412171, 1 Recording Buffer
Overflow
A image exceeding a recording
buffer is input.
Contact your dealer.
412173, 1 Fatal System Failure Fatal system error. Reboot au-
tomatically after an error oc-
curred.
If the error re-occurs, contact
your dealer.
412175, 1 LongTermDevice is
stopped from recover-
ing
The data cannot be recorded to
the long term device more than
ten minutes.
Restart VDR. To restart the
VDR, open the DCU door with
its key and turn on the AC and
BATTERY switches on the
power control panel, then turn
the switches on after shut-
down of the DCU. If the error
re-occurs, contact your deal-
er.
412176, 1 FixedDRU is stopped
from recovering
The data cannot be recorded to
the Fixed DRU more than ten
minutes.
412177, 1 FloatDRU is stopped
from recovering
The data cannot be recorded to
the Float-free DRU more than
ten minutes.
Confirm that the capsule is
seated in the bracket correct-
ly, then restart VDR. To restart
the VDR, open the DCU door
with its key and turn on the AC
and BATTERY switches on
the power control panel, then
turn the switches on after
shutdown of the DCU. If the
error re-occurs, contact your
dealer.