3. TROUBLESHOOTING
3-3
412218, 1 Fail MIC Test Contact your dealer. Caution
Cat: B
Meaning: This alert is issued when the microphone test fails. The microphone test is
run every 12 hours during normal operation.
Remedy: Contact your dealer to check the equipment.
412218, 2 Lost Audio IF Restart the VDR. Caution
Cat: B
Meaning: Audio IF Board has been disconnected more than 60 seconds.
Remedy: Check the connection with the Audio IF Board, then restart the VDR. To re-
start the VDR, open the DCU door with its key and turn on the AC and BATTERY
switches on the power control panel, then turn the switches on after shutdown of the
DCU.
412511, 1 Rec Fail Fixed DRU Restart VDR. Caution
Cat: B
Meaning: Fixed DRU is unable to write.
Remedy: Check the connection with the Fixed DRU, then restart the VDR. To restart
the VDR, open the DCU door with its key and turn on the AC and BATTERY switches
on the power control panel, then turn the switches on after shutdown of the DCU.
412511, 2 Rec Fail Float DRU Restart VDR. Caution
Cat: B
Meaning: Float-free DRU is unable to write.
Remedy: Check that the capsule is seated in the bracket correctly, then restart the
VDR. To restart the VDR, open the DCU door with its key and turn on the AC and BAT-
TERY switches on the power control panel, then turn the switches on after shutdown
of the DCU.
412511, 3 Rec Fail Long Term Restart VDR. Caution
Cat: B
Meaning: Long Term Device is unable to write.
Remedy: Restart the VDR. To restart the VDR, open the DCU door with its key and
turn on the AC and BATTERY switches on the power control panel, then turn the
switches on after shutdown of the DCU. If the error re-occurs, contact your dealer.
412511, 4 Record Stop Restart VDR. Caution
Cat: B
Meaning: Inside temperature of DCU is very high, and VDR stopped recording.
Remedy: Restart the VDR. To restart the VDR, open the DCU door with its key and
turn on the AC and BATTERY switches on the power control panel, then turn the
switches on after shutdown of the DCU. If the error re-occurs, contact your dealer.