COMM Port
DE-9 Communications port can also provide power. Pin 2, Pin 3, and Pin
5 can be used for non-Furman RS-232 devices and protocols. Please
note that +/- 12VDC power is provided on this interface. The user must
verify pin assignment and electrical compatibility with other manufac-
turer’s equipment before connecting to this port.
COMM/
POWER
UNSWITCHED
DELAY 1
DELAY 2 DELAY 3
120~V, 50/60/HZ
15A MAX
FORCE OFF
DELAY 3
+12V
STAT
REM
GND
NO
NC
C
FO
FO
P
P
S
S
OUT
IN
SMARTSEQUENCING
REMOTE PORT
CLASS 2 WIRING
COMM/
POWER
5
4
3
2
6
7
8
9
1
ACCESSORY POWER ONLY
(NEGATIVE 12VDC RETURN)
RECEIVE DATA
TRANSMIT DATA
ACCESSORY POWER ONLY
SIGNAL GROUND
ACCESSORY POWER ONLY
REQUEST TO SEND
CLEAR TO SEND
ACCESSORY POWER ONLY
(POSITIVE 12V)
PIN NO.
1
2
3
4
5
6
7
8
9
PIN 1 - ACCESSORY POWER ONLY
(NEGATIVE 12VDC RETURN)
PIN 2 - TRANSMIT DATA
PIN 3 - RECEIVE DATA
PIN 4 - ACCESSORY POWER ONLY
PIN 5 - SIGNAL GROUND
PIN 6 - ACCESSORY POWER ONLY
PIN 7 - REQUEST TO SEND
PIN 8 - CLEAR TO SEND
PIN 9 - ACCESSORY POWER ONLY
(POSITIVE 12V)
DE-9 FEMALE CONNECTOR RS-232
DE-9 Communications port can also provide power. Pin 2, Pin 3, and Pin 5 can be used for
non-Furman RS-232 devices and protocols. Please verify pin assignment and protocol of
another manufacturer’s device before connecting to port.
IMPORTANT, PLEASE READ
Outlets and Plugs:
The CN-1800S unit’s four rear panel outlet pairs are standard 120V,
15A duplex types. These outlets are widely spaced, to accommodate one
bulky plug-mounted “wall wart” power supply in each without covering up
an adjacent outlet. The front panel outlet is limited to 15 Amp use and is
filtered. The CN-1800S also uses a 14AWG 15 Amp line cord.
COMM/
POWER
UNSWITCHED
DELAY 1
DELAY 2 DELAY 3
120VAC, 50/60/HZ
15A MAX
FORCE OFF
DELAY 3
+12V
STAT
REM
GND
NO
NC
C
FO
FO
P
P
S
S
OUT
IN
SMARTSEQUENCING
REMOTE PORT
CLASS 2 WIRING
Setup and Troubleshooting
As discussed at the introduction, in order to prevent expensive repairs to
speaker enclosures, a power sequencer or multiple power sequencers
are employed to coordinate AC power to an A/V system. The amplifiers
receive AC power last when a system is turned on and amps have the
AC power cut before the signal processing is turned off. There are many
applications besides those pro audio applications discussed here and
SmartSequencing opens up many possibilities. In regards to pro audio,
we cover the basics within our documentation, yet this does not mean
that other applications cannot garner the benefits of SmartSequenc-
ing. Security and IT professionals can also benefit from remote power
management and power sequencing. Please feel free to consult a Furman
professional to answer any questions or to address the needs for any
particular installation.
Single Unit Set Up
Basic installation of the CN-1800S is ready to go out of the box. The
default DIP Switch settings should be appropriate for most applications.
Plug amplifiers into DELAY 3 or divide them into two groups and plug
one group through DELAY 2 and the other through DELAY 3. Low level
equipment such as mixers and signal processors should use DELAY 1.
Equipment incorporating special needs such as a DVR or offline UPS units
should use the UNSWITCHED outlets, e.g. equipment that must respond
to wireless remote actuation, such as projector. We suggest keeping the
front panel UNSWITCHED outlet free for equipment that is used temporar-
ily. The Key Switch can be used as the main method of On Off operation
or the Key Switch may be set to Remote and the Start Sequence pushbut-
ton can be used for On Off operation. If the Start Sequence pushbutton is
preferred over the Key Switch, simply do not use the pushbutton’s cover
shield. Once all AC connections have been made, test the set-up and
calibrate the timing range with a small screw driver if necessary. Then
secure the Matrix’s cover shield back into place.
Breaker Overload
The overall current capacity of the CN-1800S is 15 Amps. This refers
to the combined steady-state current drawn by all devices plugged into
all of its nine outlets. If this combined current level exceeds 15 Amps at
any time, the circuit breaker will trip, cutting off power to the connected
equipment. If this occurs, the operator must reduce the load by unplug-
ging one or more units from the CN-1800S. Then push the button on the
circuit breaker (on the front panel) in order to reset it. Although 15 Amps
is an absolute limit, the CN-1800S will allow the operator to come as
close as possible to using the full 15 Amps. Power sequencing greatly
reduces the risk of tripping the breaker because the CN-1800S handles
large but temporary inrush currents in stages, rather than simultaneously,
allowing each stage to settle to its steady-state current draw before the
next stage is powered. If for any reason, reasonable efforts are made
to resolve breaker trips and trips continue, please to do not hesitate to
contact Furman technical support.