Furman SmartSequencer CN-1800S handleiding
Handleiding
Je bekijkt pagina 13 van 16

12
Rear Panel Overview
Unswitched Outlet Bank and Power Indicator
This duplex bank provides power at all times when the CN-1800S is
plugged in and operating under normal power conditions. The duplex
however, is protected by the EVS feature. The CN-1800S must have
its power recycled to clear the state. If the EVS feature is triggered, the
source voltage must return to within tolerable conditions (90V-130V) and
the EVS error must be cleared. Note: If the CN-1800S DIP Switch Posi-
tion 9 is ON or UP, the unit should self-reset and clear the state automati-
cally. These outlets, as all outlets on the CN-1800S, feature LiFT filtering.
This duplex is not affected by the FORCE OFF feature and AC power will
continue to be available at the UNSWITCHED duplex even if FORCED OFF
is triggered. A Green LED to the right of this bank indicates AC power is
present.
Delay Banks
The CN-1800S rear panel provides three pairs of SWITCHED outlets.
These switched outlet pairs/duplexes are labeled DELAY 1, DELAY 2 and
DELAY 3. When the unit’s SEQUENCE ON function is initiated, DELAY 1
outlet bank receives power instantly, DELAY 2 outlet bank receives power
0-330 seconds later and DELAY 3 outlet bank receives power 0-330
seconds after DELAY 2 outlet bank is powered. When OFF is initiated, the
sequence order is reversed, with DELAY 3 losing power instantly, DELAY
2 bank losing power 0-330 seconds later and DELAY 1 outlet bank los-
ing power 0-330 seconds after DELAY 2 bank is shut down. The delay
intervals may be altered at the Time Delay Adjustment control pot and DIP
settings 1, 2, & 3. The control pot is adjustable with a screwdriver and
both features are located under the security shield, at the center of the
front panel. The combination of the Time Delay Adjustment and the DIP
setting can up provide up to 7 minutes of delay time.
COMM/
POWER
UNSWITCHED
DELAY 1
DELAY 2 DELAY 3
120~V, 50/60/HZ
15A MAX
FORCE OFF
DELAY 3
+12V
STAT
REM
GND
NO
NC
C
FO
FO
P
P
S
S
OUT
IN
SMARTSEQUENCING
REMOTE PORT
CLASS 2 WIRING
DELAY 1
OUTLET BANK
DELAY 2
OUTLET BANK
DELAY 3
OUTLET BANK
COMM/
POWER
FORCE OFF
DELAY 3
+12V
STAT
REM
GND
NO
NC
C
FO
FO
P
P
S
S
OUT
IN
SMARTSEQUENCING
REMOTE PORT
CLASS 2 WIRING
SmartSequencing Barrier Strip (2)
Primary poles connect OUT to Secondary
poles of next SmartSequencing device.
Secondary poles connect IN from Primary
poles of previous SmartSequencing device.
NOTE: Chain units in series.
COMM/
POWER
FORCE OFF
DELAY 3
+12V
STAT
REM
GND
NO
NC
C
FO
FO
P
P
S
S
OUT
IN
SMARTSEQUENCING
REMOTE PORT
CLASS 2 WIRING
Remote Barrier Strip (1)
+12V - Main DC terminal output for
remote triggering
STAT - DC terminal output for a
remote LED indicator (ANODE)
REM - Main terminal input for remote
triggering
GND -
Terminal for remote LED status
and/or triggering (CATHODE)
Barrier Strip (1) – 4 Pin
The Remote Barrier strip allows
one or more remote location
switches to be connected to the
CN-1800S. The switch or switches
used may be either a momentary
or maintained-contact type. In the
Terminal Barrier Strips
Barrier Strip (2) – 4 Pin
The SmartSequencing Barrier Strip is used to connect and daisy-chain
other SmartSequencing units together. A pair of conductors between the
Primary OUT terminals and the Secondary IN terminals is all that is re-
quired. The recommended wire gauge is 24AWG, but other wire gauges
are possible if not available.
COMM/
POWER
FORCE OFF
DELAY 3
+12V
STAT
REM
GND
NO
NC
C
FO
FO
P
P
S
S
OUT
IN
SMARTSEQUENCING
REMOTE PORT
CLASS 2 WIRING
Relay Barrier Strip (3)
FORCE OFF Provides immediate
shutdown by fire alarm
Delay 3 - Provides dry contact
closures for relays
(max. 1A @ 24VDC)
Delay 3 operates with Furman MP-20, ASD-120, etc.
barrier’s top two poles. If by chance this latest Furman Sequencer,
the CN-1800S is used in conjunction with legacy Furman sequencing
products, such as the ASD-120, the DELAY 3 pole section can be used to
trigger the older product. The DELAY 3 section provides a dry contact clo-
sure timed in series with the DELAY 3 outlet bank. The DELAY 3 contact
closure will work in either normally closed (NC) or a normally opened (NO)
fashion. Please note, when the indicator DELAY 3 on the front panel is lit,
this will indicate the DELAY 3 terminal poles have shorted the Delay 3 dry
contact, Common (C) to Normally Open (NO). If all Delay LEDs are off, the
Delay 3 dry contact will short Common (C) to Normally Closed (NC).
Barrier Strip (3) – 5 Pin
This Relay Barrier strip performs
two functions. The FORCE OFF sec-
tion provides terminals for initiating
an immediate shutdown with a
dry contact closure. Fire alarms
and other safety measures can
interface this section on the
COMM/
POWER
UNSWITCHED
DELAY 1
DELAY 2 DELAY 3
120VAC, 50/60/HZ
15A MAX
FORCE OFF
DELAY 3
+12V
STAT
REM
GND
NO
NC
C
FO
FO
P
P
S
S
OUT
IN
SMARTSEQUENCING
REMOTE PORT
CLASS 2 WIRING
COMM/
POWER
UNSWITCHED
DELAY 1
DELAY 2 DELAY 3
120VAC, 50/60/HZ
15A MAX
FORCE OFF
DELAY 3
+12V
STAT
REM
GND
NO
NC
C
FO
FO
P
P
S
S
OUT
IN
SMARTSEQUENCING
REMOTE PORT
CLASS 2 WIRING
most basic MOMENTARY configuration, only a Normally Open SPST push
button switch connected between REM and +12V is needed to initiate
a remote ON or OFF sequence. To support this configuration, DIP switch
positions 4, 6, and 7 should be in the ON or UP position. The REMOTE
Barrier strip also provides for an externally mounted LED status indica-
tor using the STAT and GND pins. The Status LED should be connected
such that its Anode (the longer lead) is connected to the STAT pin and its
Cathode is connected to the GND pin.