In addition, it should be noted, multiple Primary Units, in Momentary
Mode, could be utilized in a complex SmartSequencing chain. The chal-
lenge is having each Momentary Primary controlling an isolated Second-
ary SmartSequencing chain. Once more, any Primary Start Sequence
button could initiate a cycle up or cycle down; keeping in mind this
sophisticated operation is only possible using the Remote Pole contacts of
Momentary Mode Primary units; and then of course, using the SmartSe-
quencing ports for the Secondary chain. As previously stated, the front
panel Start Sequence pushbutton may be used in conjunction with one or
more Remote Momentary switches connected to a Primary Remote Pole
terminal strip. SmartSequencers set in Momentary Mode have optional
possibilities.
The DIP 7 factory default position is Maintained Mode. Maintained switch-
es are generally most convenient when there is only one remote location.
It is important to note, SmartSequencing units also come factory-set
for simple Maintained On operation (DIP 5 OFF or DOWN, DIP 6 OFF or
DOWN, DIP 7 OFF or DOWN), as opposed to Maintained Off. Maintained
Off is a state whereby a device is OFF until a maintained closure forces it
ON. Maintained On is the opposite and no “shorted” contact is necessary,
the device is ON until a remote contact is shorted. And besides the one
momentary mode, the CN-1800S actually has many maintained contact
switching solutions. As mentioned previously, two maintained functions
are reserved to the FORCE OFF safety setting DIP 4, which has prece-
dence over DIP 7. Below are three typical Remote Switch Maintained
Modes of operation with regard to DIP 5, DIP 6, and DIP 7:
Maintained On (factory default)
REM to +12V = OFF
Setting DIP 5 OFF or DOWN, DIP 6 OFF or DOWN, DIP 7 OFF or DOWN,
the dry contact connection across the REM terminal to the +12V terminal
initiates an OFF sequence. Disconnecting initiates an ON sequence. If
the cable run is long, it is recommended that the REM wire be tied to the
SmartSequencer’s GND terminal during ON operation rather than leaving
it floating. This will require the use of a third conductor and a double-
throw switch.
Maintained Off
REM to +12V = ON
Setting DIP 5 ON or UP, DIP 6 OFF or DOWN, DIP 7 OFF or DOWN, the
dry contact connection across the REM terminal to the +12V terminal
initiates an ON sequence. Disconnecting initiates an OFF sequence. If
the cable run is long, it is recommended that the REM wire be tied to the
SmartSequencer’s GND terminal during OFF operation rather than leaving
it floating.
Maintained Off (option 2)
REM to GND = ON
Setting DIP 5 OFF or DOWN, DIP 6 ON or UP, DIP 7 OFF or DOWN, the dry
contact connection across the REM terminal to the GND terminal initiates
an ON sequence. Disconnecting initiates an OFF.
DIP Switch position 8 determines the unit’s role in the SmartSequenc-
ing™ hierarchy. If DIP Switch 8 is in the UP or ON position, the unit is set
as the Primary Sequencer. If DIP Switch 8 is in the OFF or DOWN posi-
tion, the CN-1800S will operate as a Secondary Sequencer. In an array
of sequencers connected via SmartLink, there can be only one Primary
Sequencer, and multiple (up to 99) Secondary Sequencers. A Primary Se-
quencer sends commands to a Secondary Unit. Please remember, a pair
of conductors between the Primary OUT terminals and the Secondary IN
terminals is all that is required. Which terminals are used at the IN port
or the OUT port does NOT matter, the wiring scheme is indiscriminate.
Furthermore, the Primary Sequencer has an active DE-9 RS-232 port
that can be used to communicate with a local RS-232 control system or
an Ethernet BlueBOLT adaptor. When a SmartSequencer is selected as a
Secondary Unit (DIP 8 Down or OFF), the unit’s RS-232 port is deacti-
vated. Key Switch and Force Off function will also defeat the RS-232 port
functions regardless of Primary or Secondary distinction. Please refer to
SmartSequencing™ 101 page 6.
DIP Switch position 9 sets the EVS (Extreme Voltage Shutdown) recovery
mode that the CN-1800S will employ. If Auto-Reset has been selected
(DIP Switch position 9 ON or UP), the CN-1800S will attempt to re-set
automatically within 5 seconds after the EVS condition has subsided.. If
Manual Reset has been selected (DIP Switch position 9 is OFF or DOWN)
the CN-1800S will not automatically reinstate power after the EVS condi-
tion has subsided. Instead, the user must use the key switch to clear the
EVS error.
The EVS condition will be triggered if the incoming voltage exceeds 140V,
or falls below 80V. Once the EVS has been triggered, all outlets will be
disabled and the Extreme Voltage LED will illuminate. The EVS reset
behavior will depend on the setting of DIP Switch 9. If the CN-1800S has
been configured for manual reset, an operator must manually turn the
affected unit’s key switch to OFF and then back to REMOTE or ON. Please
note, if there is an underlying wiring fault, EVS triggers may continue to
be encountered. If this is the case, an operator should avoid resetting the
unit without first checking the source of the problem and perhaps chang-
ing the AC source.
Power Indicators
PRIMARY LINK
SECONDARY LINK
ETHERNET
DELAY 1
DELAY 2
DELAY 3
POWER
PROTECTION OK
EXTREME VOLTAGE
UNSWITCHED
START
SEQUENCE
15 AMPS
PUSH TO RESET
ON
OFF
REMOTE
DLY
ADJ
1 2 3 4 5 6 7 8 9
1M
1 2 3 4 5
2M
4M
N.O.
N.C.
12V ON
12V OFF
GND
ON
MOM
MNT
PRI
SEC
EVS AUTO
MANUAL
6 7 8 9
POWER: The POWER LED is normally illuminated
Green whenever the unit is receiving AC power and
the UNSWITCHED outlets are active.
PROTECTION OK: The PROTECTION OK LED is
normally illuminated Green when the CN-1800S is
receiving AC power and the CN-1800S protective
circuitry is operational. An unlit PROTECTION OK
LED may indicate that damage has occurred (e.g.
compromised due to moisture). Although the SMP
and EVS features may still function, if this LED is
not illuminated, please contact the Furman Service
Department.
PRIMARY LINK
SECONDARY LINK
ETHERNET
DELAY 1
DELAY 2
DELAY 3
POWER
PROTECTION OK
EXTREME VOLTAGE
UNSWITCHED
START
SEQUENCE
15 AMPS
PUSH TO RESET
ON
OFF
REMOTE
DLY
ADJ
1 2 3 4 5 6 7 8 9
1M
1 2 3 4 5
2M
4M
N.O.
N.C.
12V ON
12V OFF
GND
ON
MOM
MNT
PRI
SEC
EVS AUTO
MANUAL
6 7 8 9
PRIMARY LINK
SECONDARY LINK
ETHERNET
DELAY 1
DELAY 2
DELAY 3
POWER
PROTECTION OK
EXTREME VOLTAGE
UNSWITCHED
START
SEQUENCE
15 AMPS
PUSH TO RESET
ON
OFF
REMOTE
DLY
ADJ
1 2 3 4 5 6 7 8 9
1M
1 2 3 4 5
2M
4M
N.O.
N.C.
12V ON
12V OFF
GND
ON
MOM
MNT
PRI
SEC
EVS AUTO
MANUAL
6 7 8 9
Bekijk gratis de handleiding van Furman SmartSequencer CN-1800S, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | Furman |
| Model | SmartSequencer CN-1800S |
| Categorie | Niet gecategoriseerd |
| Taal | Nederlands |
| Grootte | 3240 MB |