10
A QUALIFIED SERVICE MAN OR GAS APPLIANCE INSTALLER
MUST MAKE THE GAS SUPPLY CONNECTION.
Leak testing of the appliance shall be conducted by the installer
according to the instructions given.
You must install the supplied connection parts seen here in this
configuration to the main gas manifold on the appliance. Issues arising
from a failure to do so will not be covered by warranty.
Do not install the pressure regulator backwards as the gas will not flow
correctly. Check that the arrow on the back points in the direction of
gas flow.
Parts required for connection from gas supply to regulator are the
responsibility of the installer / owner
FLEXIBLE APPLIANCE
CONNECTOR
APPLIANCE PRESSURE
REGULATOR
90° STREET
ELBOW
ATTENTION
Use Teflon tape rated for gas applications at all threaded connections.
Do not overtighten the connection at the manifold or you could
damage the gasket causing a leak.
WARNING
If the line pressure supplying the appliance pressure regulator
exceeds 14 inches W.C. (any gas), an external regulator must
be installed in the gas line ahead of the appliance regulator to
reduce the pressure to no more than 14 inches W.C. Failure to do
this can result in malfunction and damage to the appliance.
Important Notes for Gas Connection
The appliance and its individual gas shutoff valve must be
disconnected from the gas supply piping system during any pressure
testing of that system at test pressures in excess of 1/2 psi (3.5 kPa).
The appliance must be isolated from the gas supply piping system
by closing its individual manual shut-off valve during any pressure
testing of the gas supply piping system at test pressures equal to or
less than 1/2 psi (3.5 kPa).
All supply piping, except as noted, should use common National
Pipe Thread (N.P.T.). For all pipe connections use an approved pipe
joint compound resistant to the action of LP gas.
This appliance is designed for use with NG gas or LP gas.
The gas pressure regulator is supplied with this appliance.
It must be installed in the gas way ahead of the manifold entrance.
It is pre-set for use with natural gas. To use it with different gas it
must be converted, as described in the Gas conversion paragraph.
If at any time the appliance is to be used with a different type of
gas, all the conversion adjustments must be made by a qualified
technician before attempting to operate the cooktop on that gas.
The gas should be supplied to the appliances pressure regulator,
at line pressure between 6 and 14 inches of water column for NG,
and between 11 and 14 inches of water column for LP.
GAS REQUIREMENTS
NATURAL GAS WC
Manifold Pressure 5" (12.5 mb)
Min Line Pressure 6" (15 mb)
Max Line Pressure 14" (34.9 mb), .5 psi (3.5 kPa)
LP GAS WC
Manifold Pressure 10” (25 mb)
Min Line Pressure 11” (27.4 mb)
Max Line Pressure 14” (34.9 mb), .5 psi (3.5 kPa)
IMPORTANT
• NEVER REUSE OLD CONNECTORS WHEN INSTALLING
THIS COOKTOP.
To reduce the likelihood of gas leaks, apply teflon tape or a
thread compound approved for use with LP or Natural gases
to all threaded connections.
Apply a non-corrosive leak detection fluid to all joints and
fittings in the gas connection between the supply line shut-off
valve and the cooktop inlet.
Check for leaks!
Bubbles appearing around fittings and connections will
indicate a leak. If a leak appears, turn off supply line gas
shut-off valve, tighten connections, turn on the supply line gas
shutoff valve, and retest for leaks. Never test for gas leaks with
an open flame.
• NEVER TIGHTEN TO MORE THAN 35 ft lbs OF TORQUE.