Friedrich ZoneAire Select PZH07K3SB handleiding

37 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 13 van 37
13
C. INSTALLATION OF THE UNIT
Figure C.4.1 (Internal Drain Kit)
PXDR10
QUANTITY DESCRIPTION
2
1
1
3
4
2
2
COVER PLATES
MOUNTING PLATE
DRAIN TUBE
MOUNTING PLATE GASKET
#10 X ½” SHEET METAL SCREWS
#10-24 X ½ ” MACH. SCREWS
#10-24 X ½" LOCKNUTS
C.4 Install Unit
C.4.1 Install Internal Drain Kit (If applicable)
1. The PXDR10 Drain Kit if applicable, must be installed before the
wall sleeve is installed into the wall.
NOTE: Determine whether drain will be located within the wall, on
the indoor side, or will drain to the exterior of the building. Follow
appropriate instructions below depending on your particular type of
installation.
Internal Drain
NOTE: If installing an internal drain, you MUST install a drain kit on
the wall sleeve before the wall sleeve is installed.
1. Locate the drain within the “Preferred” area of best drainage.
Maintain at least a ½” clearance from the embossed area.
2. Using the mounting plate with the ½” hole as a template, mark
and drill two, 3/16” mounting holes and a ½” drain hole in the
sleeve bottom.
3. Remove the backing from the gasket and mount it on the flat
side of the mounting plate. (See Figure C.4.2). Insert the
drain tube through the hole in the gasket and mounting plate
so the tube flange will be against the wall sleeve.
4. Position the assembly beneath the drilled holes and secure it
with #10-24 x ½” machine screws and lock nuts provided. Seal
the tops of the screws with silicone caulking.
5. Use ½” I.D. copper tube, PVC pipe, or vinyl hose (obtained
locally) to connect the internal drain tube to the drain system
in the building.
6. Referring to C.4.2 locate and assemble the (2) two cover plates and
gaskets over the drain holes at the rear of the wall sleeve. Attach
them with the #10 sheet metal screws provided. Make certain that the
four overflow slots at the rear of the wall sleeve are not blocked (See
drawing of the back of the sleeve Figure C.4.2).
7. If a deep wall extension (PDXWSEXT) is used, after installing
the field supplied flashing, caulk as required. Be sure to caulk
around the flashing and the wall sleeve where the hole was
drilled for the drain tube.
DRAIN TUBE
SIDE VIEW
FRONT VIEW
WALL SLEEVE
OPTIONAL AREA
PREFERRED AREA-
NO FOAM INSULATION
NOTE: IF THE DRAIN MUST BE
LOCATED IN THE OPTIONAL
AREA, THE FOAM INSULATION
MUST BE CUT AWAY AND
REMOVED TO ALLOW ACCESS
TO THE DRAIN.
NUT
MOUNTING
PLATE
GASKET
SCREW
3"
OPTIONAL
AREA MUST BE 18”-21” CENTERED
FROM SIDEW
ALLS TO ENSURE DRAINAGE

Bekijk gratis de handleiding van Friedrich ZoneAire Select PZH07K3SB, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkFriedrich
ModelZoneAire Select PZH07K3SB
CategorieAirco
TaalNederlands
Grootte6056 MB