Handleiding
Je bekijkt pagina 30 van 37

30
J. STARTUP AND OPERATION
J.4 Control Panel Operation
IMPORTANT : When unit is first started,high humidity conditions can cause condensation to form on discharge grille.Keep doors and windows
closed .Room humidity will decrease and moisture will evaporate.
OPERATION
IMPORTANT : When unit is first started,high humidity conditions can cause condensation to form
on discharge grille.Keep doors and windows closed.Room humidity will decrease and moisture will
evaporate.
Fig.26–PTAC CONTROLS
17
High
Low
Auto
Constant
Fan
Cool
Heat
Fan Speed Mode
Temperature
Power
ABOUT THE CONTROLS ON YOUR UNIT
NOTE:In case of a power failure,the unit will remember the last programmed settings and will
restart to those settings.
1.When the unit is in off mode, turn on the unit by Power; if pressing up/down button, dual-8
will off after indoor temperature displays for 15s; if pressing mode button, controller will resume
to related state, and operation indication lamp will on (mode button including cooling mode button,
heating mode button and fan mode button)
* Power: It will shift when the unit is Power by Power.
* Cooling mode button: when the unit is on, it will run under cooling mode; when the unit is off, press
cooling mode button, controller is on and runs under cooling mode.
* Heating mode button: when the unit is on, it will run under heating mode; when the unit is o ff, press
heating mode button, con troller is on and runs under heating mode.
* Constant Fan button: when the unit is on, it will run under fan mode; when the unit is off, press fan mode
button, controller is on and runs under fan mode.
* Low speed button: when the unit is on, low fan will be chose if pressing low fan button.
* High speed button: when the unit is on, high fan will be chose if pressing high fan button.
Auto
speed button: When the unit is on, press Auto button,the unit will run at the mode automatically
adjusted according to ambient temperature.
*
*
UP/DOWN: Adjust preset temperature
61-86°F 16-30°C by UP/DOWN.
2.Every button is valid when the unit is on.
ABOUT THE CONTROLS ON YOUR UNIT
NOTE: In case of a power failure,the unit will remember the last programmed settings and will restart to those settings.
1. When the unit is in off mode, turn on the unit by Power; if pressing up/down button, dual-8 will off after indoor temperature displays for 15s;
if pressing mode button, controller will resume to related state, and operation indication lamp will on (mode button including cooling mode
button, heating mode button and fan mode button)
2. Every button is valid when the unit is on.
• Power: It will shift when the unit is Power by Power.
• Cooling mode button: when the unit is on, it will run under cooling mode; when the unit is off, press cooling mode button, controller is on
and runs under cooling mode.
• Heating mode button: when the unit is on, it will run under heating mode; when the unit is off, press heating mode button, controller is on
and runs under heating mode.
• Constant Fan button: when the unit is on, it will run under fan mode; when the unit is off, press fan mode button, controller is on and runs
under fan mode.
• Low speed button: when the unit is on, low fan will be chose if pressing low fan button.
• High speed button: when the unit is on, high fan will be chose if pressing high fan button.
• Auto speed button: When the unit is on, press Auto button,the unit will run at the mode automatically adjusted according to ambient tem-
perature.
• UP/DOWN: Adjust preset temperature 61-86°F 16-30°C by UP/DOWN.
Figure J.4.1
Bekijk gratis de handleiding van Friedrich ZoneAire Select PZE09K3SB, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | Friedrich |
| Model | ZoneAire Select PZE09K3SB |
| Categorie | Airco |
| Taal | Nederlands |
| Grootte | 6056 MB |