J. STARTUP AND OPERATION
J.5 Allocation Mode
Allocation mode will be started up if pressing the buttons of low speed and Setpoint down for 5S when the unit is on in 30S . After entering
into allocation mode, adjust temperature compensation by buttons which leads the unit in on/off condition, and it acts after it overloads 3S; if
ambient temperature changing leads the unit in on/off condition, it will act after exit allocation mode.
Under allocation mode: Choose below 4 allocation modes by low speed button.
First Mode: Fahrenheit/Celsius display mode
The Fahrenheit/Celsius display mode will be shifted if pressing Setpoint up or Setpoint down.
F means Fahrenheit display mode C means Celsius display mode.
Second Mode: Adjust cooling temperature compensation value mode
Press Setpoint up/Setpoint down will increase/decrease compensation temperature 1°F(or °C).
The adjust range of indoor ambient temperature compensation value is -6°F~+6°F(-3°C~+3°C)
(cooling mode LED is on.)
Third Mode: Adjust heating temperature compensation value mode
Press Setpoint up/Setpoint down will increase/decrease compensation temperature 1°F (or °C)
The adjustment range of indoor ambient temperature compensation value is -6°F~+6°F(-3°C~+3°C)
(heating mode LED is on.)
The temperature compensation is default 0 and allocates different compensation value under cooling and heating mode, the compensation
value can not be adjusted under fan mode
Forth Mode: Display shift of preset temperature and ambient temperature under heating and cooling mode.Display of preset temperature and
ambient temperature can be shifted if pressing Setpoint up or Setpoint down. Preset temperature display: dual-8 displays SP, after exiting
allocation mode, preset temperature will display under heating and cooling mode.
Ambient temperature display: dual-8 displays AA, after exit allocation mode, ambient temperature will display under heating and cooling mode.
In below situation: preset temperature will display 10S, then display ambient temperature.
1. Press mode button. (mode button includes: cooling mode button, heating mode button)
2. Energization after power off.
3. Turn off the unit after turn on unit.
4. EM off after on.
5. Adjust preset temperature by Setpoint up and Setpoint down.
Exiting measure of allocation mode: for above allocation mode, there is no button action if pressing mode button (including cooling mode
button, fan mode button and heating mode button) or in 30S, the unit will exit allocation mode.