IR/S (IR/serial) or IR port — This port provides unidirectional communication to
control a switcher or a display via RS-232 or IR. For IR control, one or two IR emitters
can be connected with a maximum of 50 feet (15 m) distance from port to emitter.
RS models — On all MLC 60 Series RS models, this port is labeled Port B
IR/S. It can be set up via the configuration software to send out unidirectional
RS-232 (the default) or IR commands. In the configuration software, this port is
called Port B (IR/S).
MLC 62 IR D — On the IR-only model, this port is labeled Port A IR and issues
only IR commands. In the configuration software, this port is called Port A (IR).
E
Com port (RS models only) — This serial port, labeled Port A Com, provides
unidirectional communication to control a switcher or a display via RS-232. In the
configuration software, this port is called Port A (RS-232).
F
PWR (power) connector — Connect the supplied 12 VDC, 1 A power supply (or
any other Extron approved power supply capable of providing 12 VDC) to this 2-pole
captive screw connector.
ATTENTION:
The power supply must not be permanently fixed to the building structure or
similar structures.
La source d’alimentation ne devra pas être fixée de façon permanente à une
structure de bâtiment ou à une structure similaire.
Do not place the power supply within environmental air handling spaces or
the wall cavity.
Ne pas placer les sources d’alimentation dans une zone de traitement de l’air
ni dans une cavité murale.
The installation must be in accordance with the applicable provisions of
the National Electrical Code ANSI/NFPA 70, Article 725 and the Canadian
Electrical Code, Part 1, Section 16.
Cette installation doit toujours être en accord avec les mesures qui s’applique
au National Electrical Code ANSI/NFPA70, article725, et au Canadian
Electrical Code, partie1, section16.
The power supply must be located within the same vicinity as the Extron AV
processing equipment in an ordinary location, Pollution Degree 2, secured to
a podium, a desk, or an equipment rack within a dedicated closet.
La source d’alimentation doit être située à proximité de l’équipement
audiovisuel Extron dans un emplacement habituel, avec un degré de
pollution 2, fixée à une estrade, un bureau, ou dans une baie technique à
l’intérieur d’un placard dédié.
Always use a power supply provided by or specified by Extron. Use of an
unauthorized power supply voids all regulatory compliance certification and
may cause damage to the supply and the end product.
Utilisez toujours une source d’alimentation fournie ou recommandée par
Extron. L’utilisation d’une source d’alimentation non autorisée annule toute
conformité réglementaire et peut endommager la source d’alimentation ainsi
que le produit final.
G
Reset LED — Indicates the status of a reset in progress.
H
Reset button — Press this button to initiate factory firmware or configuration resets
(see Resetting the MLC Using the Reset Button on page 43).
I
DIP switches — Reserved for future use.
MLC 60 Series MediaLink Controllers • Features, Installation, and Operation 16