Rear Panel Features
See the wiring and installation sections, later in this section, for connection information.
COM
PORT A
Tx G
IR/S
PORT B RS-232
SG
D IN
IN G
RELAYS
12C
REMOTE
Tx Rx G
PWR
12V
0.4 A MAX
AA
B
B
C
C
D
D
E
E
F
F
MLC 62 IR D Rear Panel
MLC 62 RS D and MLC 64 RS D
Rear Panel
REMOTE
RS-232
Tx Rx G
IR
PORT A
SG
PWR
12V
0.4 A MAX
AA
D
D
F
F
12
R
COM
PORT A
Tx G
IR/S
PORT B
SG
D IN
IN G
PWR
12V
0.4 A MAX
RELAYS
12C
RS-232
REMOTE
Tx Rx G
II
H
H
A
A
B
B
F
F
G
G
D
D
E
E
CC
MLC 62 RS EU and
MLC 62 RS MK Rear Panel
A
Remote port
B
D In port
(RS models only)
C
Relay ports
(RS models only)
D
IR/S or IR port
E
Com port
(RS models only)
F
Pwr connector
G
Reset LED
H
Reset button
I
DIP switches
Figure 10. MLC 60 Series Rear Panels
A
Remote RS-232 port — This bidirectional RS-232 serial port can be used for
configuration and firmware updates in the same way as the USB port (see Front and
Left Side Panels on page 10). The baud rate is 9600 bps. This port can be used
as a backup for the USB Configuration port (although you cannot power a device
through it).
B
D In (digital input) port (RS models only) — This port enables the MLC to monitor
devices such as push buttons, switches, motion sensors, and moisture sensors and
provides an additional way to trigger functions on the MLC. Connect a switch or a
sensor to this 2-pole captive screw connector to initiate commands via the MLC to
the display device, switcher, or other room devices such as lights or a motorized
screen.
C
Relay ports (RS models only) — These relays allow control of room devices such
as motorized screens, lights, and projector lifts. They are normally open relays and
are rated at 24 V, 1 A. Low-power devices can be connected directly to the relay
ports, while devices requiring more than 24 V can be connected through a third-party
low-voltage controller (LVC).
MLC 60 Series MediaLink Controllers • Features, Installation, and Operation 15