You can perform two types of reset (see figure 26 on the previous page):
Resetting to the default configuration
1. While the MLC is powered on, press and hold the Reset button. The green Reset
LED lights and remains lit while the button is held.
2. After 3 seconds, the Reset LED blinks once. Release the button, then
immediately (within 1 second) press it again and release it immediately
momentary press).
When the reset is finished, the Reset LED blinks green four times, indicating that
the reset was successful.
Resetting to the factory firmware version
NOTE: This procedure does not reset the configuration on the device.
1. With the MLC powered off, press and hold the Reset button.
2. Continue to hold the button while applying power to the MLC.
3. When the reset is complete, the front panel buttons scroll. Release the Reset
button.
MLC 55 Series MediaLink Controllers • Installation and Operation 27