Extron IPCP Pro 360 handleiding
Handleiding
Je bekijkt pagina 34 van 72

IPCP Pro Series • Hardware Features and Installation
26
N
Switched AC power output (attached cable) (IPCP Pro PCS1 only) (see figure 16 on page 20) —
Provides switched (controlled) AC power output to another device.
CAUTION:
ATTENTION :
• Total length of the power cord including the small pigtail shall not be less than 1.5 m or more than 4.5 m.
• La longueur totale du câble d’alimentation, cordon compris, ne doit pas être inférieure à 1,5 m ou
supérieure à 4,5 m.
• Always use the power cord provided with the unit.
• Veillez à toujours utiliser le câble d’alimentation fourni avec l’unité.
• Should you need to use a different power cord, consult Extron Electronics prior to using the cord.
• Si vous devez utiliser un autre câble d’alimentation, contactez Extron Electronics avant d’utiliser ce câble.
R
POWER
Circuit Breaker
(power output
overcurrent
protection)
Front
Panel
10
P
R
E
S
S
T
O
R
E
S
E
T
BREAKER
50-60Hz
50-60Hz
100-240V ~ 10A MAX
100-240V ~ 10A MAX
INPUT
OUTPUT
Rear
Panel
Switched 100-240 VAC, 10 A (Max.) Power Output
• Front panel Power LED appears:
• Lit green ( ) when power output is enabled (unit outputs power)
• Off ( ) when power output is disabled (power output is off)
• Lit red ( ) when a power output overcurrent condition is detected
(the circuit breaker has been tripped) and power output is disabled.
• Front panel Power button controls power output availability.
NOTE: The front panel power switch is not a safety disconnect
device. In case of emergency, disconnect AC power from the
power input (appliance inlet) of the connected equipment.
6 inch (152 mm)
IEC Output Cable
Power input port
on an AV device
(international)
or
Power input port
on an AV device
(USA)
IEC Power Cord
Edison Power Cord
NEMA 5-15R
Adapter
Figure 23. Switched AC Power Output Connection (IPCP Pro PCS1 Only)
ATTENTION:
• When using the NEMA 5-15R receptacle adapter, connect the equipment only to a nominal 120 VAC
electrical supply source.
• Lorsque vous utilisez la prise de courant NEMA 5-15R, veillez à ne connecter le dispositif qu’à une
source d’alimentation nominale de 120 Vca.
NOTES:
• Within the United States of America use a power supply cord with conductors that are a minimum
diameter of 18 AWG.
• For international installations, use a power supply cord with conductors that are a minimum of 1.0 mm
2
.
• Make sure that the device being controlled can support an AC power cycle.
• The power state of this port is retained after power is cycled to the IPCP Pro PCS1.
AC power output can be enabled or disabled using the following:
• A configuration (created in Global Configurator or Global Scripter)
• The IPCP Pro PCS1 front panel
Power
button (see Power button (switch) and LED on page 15).
• A control within the IPCP Pro PCS1 embedded web page.
This output is protected by a 10 A circuit breaker (see Circuit breaker on page 15). For reference, the
embedded web page for the unit displays the state of the circuit breaker and the value of the combined
current load.
Rev. H: Added the
IPCP Pro PCS1
power output.
Rev. L: Added text indicating
that output power for the
PCS1 can be controlled via
web page.
Rev. L: Added text about
the current load and circuit
breaker state being shown on
the embedded web page.