display size in the signature pad corresponds exactly to a 1:1 print-out on paper. 200%
corresponds to a signature pad display magnified by a factor of two. Magnifying
simultaneously reduces the displayed area of the document.
If the Highlight signature fields in the signature device option is enabled, the position
and size of the signature fields is indicated by a blue rectangle. This option is enabled by
default.
In combination with this option, by selecting the Limit the signing area to the signature
field option, you can specify that signing is possible only in the blue area. However, we
recommend selecting this option only if the magnification level is sufficiently high, so that
the displayed signature field is sufficiently large. If this option is not selected, the entire
pad surface can be used for signing. The signature is then adjusted to the signature field
when it is inserted into the document. This option is disabled by default.
Maintenance options
The maintenance options or settings are available for all signature pads.
The unique Serial number for the signature pad is displayed. It can also be found on the
sticker (see following example image) on the rear side of the signature pad beneath the
barcode.
The Firmware version for the signature pad is also displayed. Please let us know the
version on request if you need technical support.
You can use the Adjust sensor button to recalibrate the signature pad if entries on the
signature pad are displayed offset from the pen position. A white area with a cross in the
upper-left corner now appears on the signature pad display. Please press the intersection
point of the two lines with the tip of the pen. Now the cross appears in the upper-right
corner where you need to press the intersection point again. The pad is then recalibrated
and displays the background graphic once more.
Please perform the calibration on the signature pad first and then confirm the dialog box
that opens when the adjustment is started.
Furthermore, you can use the Service menu button to access the configuration menu for
the signature pad. In this menu, you can modify settings for the display brightness or the
connection type and its configuration, depending on the particular signature pad. Further
information is provided in the manual for the signature pad on our website.
The Service menu cannot be called up for the signotec Sigma or Sigma Lite
as these settings cannot be configured.
Please make the changes on the signature pad first and then confirm the dialog box that
opens when the service menu is started:
Configuring the IP list capture plug-in
If the IP list capture plug-in has been defined as the first or second signature device,
special settings can be made for this plug-in.