39 Parameter setting
Sensor KNX T-UP Touch • Version: 05.09.2022 • Technical changes and errors excepted.
Dead man‘s switch:
Shutter
Standard:
Standard inverted:
Comfort mode:
Dead man‘s switch:
Push button down command
Release button up command
Pushbutton function • Up
• Down
• Up/Down
Control mode • Standard
• Standard inverted
• Comfort mode
• Dead man‘s switch
Behaviour for button actuation (up): short = Stop | long = Up
Behaviour for button actuation (down): short = Stop | long = Down
Behaviour in case of button actuation (up/down): short = Stop | long = Up/Down
Time between short and long
in 0.1 seconds
0 ... 50; 10
Behaviour for button actuation (up): long = Stop | short = Up
Behaviour for button actuation (down): short = Stop | long = Down
Behaviour in case of button actuation (up/down): short = Stop | long = Up/Down
Time between short and long
in 0.1 seconds
0 ... 50; 10
Repeat the step command
for a long button press (only Up)
no • every 0,1 s • ... • every 0,5 s • ... • every
2 s
Button is pushed and
released before time 1 expired
held longer than time 1
released between time 1 and 1-2
released after time 1 +2
Stopp
Up | Down | Up/Down
Stop
no more stop
Time 1 (in 0,1 s) 0 ... 50; 4
Time 2 (in 0,1 s) 0 ... 50; 20
Push button Up- | Down- | Up/Down command
Release button Stop command