38 Parameter setting
Sensor KNX T-UP Touch • Version: 05.09.2022 • Technical changes and errors excepted.
Changeover switching
Blind
Standard:
Standard inverted:
Comfort mode:
Send value • on change
• on change to 1
• on change to 0
• on change and periodically
• on change to 1 and periodically
• on change to 0 and periodically
Cycle (if sent periodically) 5 s • ... • 1 min • ... • 2 h
Command when pressing the pushbutton • Changeover switching
• do not send message
Command when releasing the pushbutton • Changeover switching
• do not send message
Pushbutton function • Up
• Down
Control mode • Standard
• Standard inverted
• Comfort mode
• Dead man’s switch
Behaviour for button actuation (up): short = Stop/Step | long = Up
Behaviour for button actuation (down): short = Stop/Step | long = Down
Time between short and long
in 0.1 seconds
0 ... 50; 10
Behaviour for button actuation (up): long = Stop/Step | short = Up
Behaviour for button actuation (down): short = Stop/Step | long = Down
Time between short and long
in 0.1 seconds
0 ... 50; 10
Repeat the step command
for a long button press
every 0.1 s • every 2 sec; every 0.5 sec
Button is pushed and
released before time 1 expired
held longer than time 1
released between time 1 and 1-2
released after time 1 +2
stop/step
Up or Down
Stop
no more stop
Time 1 (in 0,1 s) 0 ... 50; 4
Time 2 (in 0,1 s) 0 ... 50; 20