3.10.11 Error and Fault Corrections
EFLG
(These functions are reserved for authorized technicians only)
3.11 Error and Information Messages
HEAt
This message appears if you try to switch on the lamp within 5
minutes after having switched off (lamp too hot). The message
will appear on the display if the lamp doesn’t ignite within 20
seconds. The fixture will store this command and automatically
ignite the lamp after 5 minutes.
LaeR
After the ignition of the lamp was two times not successful the
display will show LAER. That means the lamp could be damaged
or even missed, the fixture is overheating or there could be a
failure on the igniter or ballast. Switch off the power supply and
solve the possible problem.
OTMP
This error message informs you that the fixture was overheating
and that the relay switches off the lamp. Pleas look for possible
reasons (fan faulty, air in/outlets blocked or very dirty, lamp
broken or very old, too high ambient temperature. Switch off the
power supply and solve the possible problem.
RsER
This message informs you that one of the fixture function wasn’t
able to do its reset correct (magnetic sensor, stepping motor,
driver on the PCB, cables, etc.). Repair the defect and start the
fixture again.