Use and maintenance manual, model “LIBERA 8 V/C - LIBERA 11 V/C”
ENGLISH
37
PHASE DESCRIPTION
Anomaly of the probe controlling the
temperature of the exhaust smoke.
Contact the authorised technician to
solve the problem.
Anomaly of the probe which controls
the ame temperature in the
combustion chamber. Contact the
authorised technician to solve the
problem.
Anomalies are warnings that reset themselves
automatically once the problem has been solved.
Press the OK to view the type of anomaly.
Alarms are warnings that, for safety reasons, will
cause the heat generator to stop immediately.
To solve some anomalies, technical intervention
by authorized personnel is required. Although the
appliance continues to function, the user must
contact the local technical assistance centre
to solve the problem. Ignoring the warning can
damage the product, even seriously, and the
warranty will be invalidated due to negligence on
the part of the customer.
18 DESCRIPTION OF ALARMS
PELLETS
The stove operation is constantly monitored by
elemento, the software (rmware) that constantly
monitors the safe functioning of the product.
When the system detects a fault or incorrect
values, for the SAFETY of the user, the appliance
always turns off immediately. An error code with
further details is displayed on the remote control.
To turn the product back on, it is necessary to
check the type of problem detected, solve it (use
the information in the alarm table below as a
reference) to reset the alarm, and then turn the
appliance back using the remote control. Long
press of the power button . The heat
generator carries out a nal cleaning cycle
anyway, and then switches OFF before allowing it
to be turned back on.
ALARM CODE REASON
01 - BLACK OUT
A blackout occurred while the stove was
operating.
SOLUTION
Check that the power cable is well inserted
both in the wall socket and in its socket on
the stove, taking care to turn it off with the
I/0 button before operating.
Follow the instructions on the remote control
and clean the brazier before trying to turn it
on again. DANGER: MALFUNCTIONING
ALARM CODE REASON
02 - NO SWITCH
ON
The pellet tank is empty or else the auger
was not filled using the appropriate menu
before switching on the appliance.
Change the type of pellet compared
to the one used for adjustments during
commissioning.
The electrical resistor responsible for ignition
is defective or not in the correct position.
SOLUTION
Load the tank and use the auger loading
function before turning the stove back on.
If possible, use a type of pellet identical to
the one used for commissioning. If this is not
possible, it may be necessary to contact
the Assistance Service to readjust the
values according to the new type of pellet.
Clean the brazier thoroughly using the ash
vacuum cleaner, especially on the right
side of the brazier, next to the hole for the
electric resistor. Avoid dumping combustion
residues into the brazier.
If the problem persists, and/or to replace
the resistor, contact the Authorized
Assistance Service.
ALARM CODE REASON
03 - PELLETS
EXHAUSTED
Pellet exhausted in the pellet tank or lack
thereof when loading into the brazier.
SOLUTION
Check the tank load and fill it if necessary.
In the “P/A Ratio" menu, check that you
have not decreased the pellet load too
much and that you have not increased
the supply of combustion air, distorting the
balance of correct combustion. Bring both
values back to zero and try again.
If the problem persists, contact the
Authorized Assistance Service.