Use and maintenance manual, model “LIBERA 8 V/C - LIBERA 11 V/C”
ENGLISH
33
Press OK to access the menu.
Press OK or to go back to the SETTINGS menu.
12.10 ANTICONDENSATION
Once activated, this function guarantees
that the ue gas temperature remains above
condensation temperature.
Condensation in the exhaust pipe is caused by
the product being used at low powers, generally
P1 or P2. Because the vast majority of the heat
produced is exchanged with the environment
(in compliance with high levels of efciency
demanded by contemporary anti-pollution
rules), exhaust temperature has been greatly
reduced. As a consequence, the exhaust fumes
are expelled at a temperature which is too low
to avoid condensation if the product is not used
correctly, that is at the nominal power (P7) or at
one slightly lower.
Moreover, failure to comply with the current laws
on product installation and the use of fuels other
than those described in Chapter 2 can cause
condensation in the ue exhaust as well.
Pay particular attention to any formation of
condensation in the exhaust pipe, as it could
severely damage the product. In this case, the
damages are not covered by the 24-month
European warranty on manufacturing defects.
Remember that the anti-condensation system,
once activated, only comes into operation when
smoke is too cold in the exhaust, protecting the
product from possible severe damage.
OPERATING PROCEDURE:
menu > user settings > settings > anticondensation
Press OK to access the menu.
Scroll the items up to USER SETTINGS, key
Press OK to access the menu.
Scroll the items up to SETTINGS, key
Access the menu by pressing OK
Scroll the items up to ANTICONDENSATION, key
Press OK to activate/deactivate the function
When this function is activated, the ame-shaped
icon displayed on the remote control is replaced
by a drop-shaped icon as soon as the system
detects low temperature in the exhaust pipe. As
the smoke temperature rises, the ame icon is
restored on-screen and the anti-condensation
system deactivated.
This function is inhibited while in wood operation.
13 CANALIZATION (Optional)
If you need to heat a room adjacent to the one
where the product is installed, it is possible to
install a single ducting kit, even after purchasing
the product. Contact your retailer for further
information.
You can nd the space for the installation of the
ducting kit on the left of the product (looking at
the appliance from the front). The channel outlet
can be either on the side or on the back of the
product, where you will nd pre-cut sheets. Please
refer to chapter 3.9 for installation instructions.
13.1 SINGLE DUCTING SETTINGS
Ducting options are explained below:
manual (off, xed speed, linked to the stove
operating power)
with temperature control - with room probe and
external thermostat (not supplied).
OPERATING PROCEDURE:
menu > user settings > canalization
Press OK to access the menu.
Scroll the items up to USER SETTINGS, key
Press OK to access the menu.
Scroll the items up to “CANALIZATION”, key
Press OK to access the CANALIZATION menu
The screen with the canalization settings will be
displayed, as in the gure below.
To manually manage the ducting, press OK on
MANUAL SETUP: