Use and maintenance manual, model “LIBERA 8 V/C - LIBERA 11 V/C”
ENGLISH
12
INSTALLATION CERTIFICATE OF CONFORMITY on
the whole Italian territory. Examples: (A) horizontal
section needed for connection to an existing
ue. Observe a minimum upward slope (3-5%) to
reduce the quantity of ash deposit in the horizontal
section of the pipe, which must not exceed 2m
(1). The existing ue must be inspectable (2).
The installation of the product (B) requires an
insulated ue (3), as the entire smoke pipe has
been mounted outside the building.
Example (C) shows a single-wall smoke duct (4)
for the indoor section. With regard to the part
located in the attic, outside the room where the
generator is installed, it is necessary to install an
insulated section, with double crossing of the slab
and the roof; the passing holes of the pipe must
respect the minimum safety distances indicated
on the labels of the sections of the ue pipe itself,
paying attention to the possible contact with the
material crossed, as is the case with:
if in contact with concrete, bricks, etc.;
• if in contact with wood, composite materials, etc.
In both cases, insert a suitable roof passage (5)
between the ue and the attic.
It is recommended to check and respect the
data on the ue plate, paying particular attention
to safety distances from combustible materials.
The previous rules also apply to connection holes
drilled on the wall.
On the lower part of the ue pipe, as well as on
the inlet of the chimney ue, a "T" type connector
(6) with inspection plug (7) has been tted for the
all the 3
types of installation.
In the upper part of the ue, for all 3 examples,
a windproof chimney pot (8) has been mounted.
For all the 3 types of installations, a grate (9) has
been provided to ensure good oxygenation of
the room where the product has been placed. In
case of hermetically sealed appliance, equipped
with direct outdoor connection of the air-intake
system, a grate is not required.
3.8 DOCUMENTS TO BE ISSUED
After installation, the installer must hand over to
the user the following:
use and maintenance manual of the appliance
(supplied by the manufacturer);
technical documents of the accessories used and
subject to maintenance;
the documentation relevant to the evacuation
system of combustion products;
System booklet;
the documentation certifying installation and
functional test;
The useful documentation for the installer’s liability
must include:
9
7
7
A
1
2
3
3
4
8
8
8
9
6
7
B
C
6
3
5
5
6
6
9
3.7 EXAMPLES OF PROPER INSTALLATION
Always refer to the standard UNI 10683 when
product installation has to be carried out by a
qualied professional, who is required to issue the