5.3 Signal input connections
The rear panel of the MIMO88 offers 8 balanced analogue signal inputs, "IN" (9),
accepting both line and microphone level signals. Input signal type selection and
management are carried out from EclerNet Manager application. Please refer to the
EclerNet Manager software manual at www.ecler.com for more information.
Signal input connectors are 3 position screw terminal block. The wiring is:
Hot or direct signal > Terminal +
Cold or inverted signal > Terminal -
Ground > Terminal
For unbalanced connection short-circuit pin to pin -.
5.4 Audio Output Connections
The rear panel of the MIMO88 offers 8 analogue
signal outputs, "OUT" (8), and two additional
"MONITOR" (10) outputs, all balanced and accepting
line level signals.
Signal output connectors are 3 position screw
terminal blocks. The wiring is:
Hot or direct signal > Terminal +
Cold or inverted signal > Terminal -
Ground > Terminal
For UNBALANCED connections, leave the terminal unconnected.