Connecting cables can be up to 500 meters with a minimum section of 0.5 mm
2
.
Consult your ECLER dealer or www.ecler.com about the WP series remote control wall
panels and other accessories available for connection to the REMOTE/VCA port.
5.9 GPO Remote Control Ports
The rear panel of the MIMO88 offers 8 NO/NC (normally open/ normally closed) relay
outputs (17). Each of these outputs may be assigned to a MIMO88 function, such as a
button of EclerNet Manager (MUTE key, SOLO key, etc.). This makes it possible to interact
with external devices such as projection screen motors or movable partitions, lights,
sirens, other equipment GPI entries, etc.3.10. Remote control RS-232 Port
5.10 Remote control RS-232 Port
The built-in RS-232 port in the rear panel allows an external device to communicate with
an MIMO88 unit via a serial connection. Said connection uses the TP-NET protocol syntax
so to enable the external device to obtain the value of any of the parameters of the
MIM088 unit (by "GET" commands) and/or modify said values (“SET” commands). See
the TP-NET protocol manual for more information.
The serial connection should comply with the following specifications:
Baud rate: 57600 (fixed, no auto negotiation)
Data bits: 8
Parity: None
Stop bits: 1
Flow control: None
WIRING RS232 DB9
RS232
DB9
Tx
Pin 2 (RxD)
Rx
Pin 3 (TxD)
Gnd
Pin 5 (Signal Gnd)