8.3.6.1 Smart Charging Prole Conguration
Figure 48. Smart Charging Profile configuration
Description
Name Name of the profile. By default, non-predefined profiles are displayed as Profile XX, where XX is the profile ID.
Frequency Type of recurrence of a charging profile.
Daily: the schedule restarts every 24 hours, at the same time
Weekly: the schedule restarts every 7 days, at the same time and day-of-the-week
Occurrence Absolute: Schedule periods are relative to a fixed point in time defined in the schedule.
Recurring: The schedule restarts periodically at the first schedule period.
Start schedule Starting point of an absolute schedule. If absent the schedule will be relative to start of charging.
Valid from Point in time at which the profile starts to be valid. If absent, the profile is valid as soon as it is received by the Charge Point.
Valid to Point in time until the profile is still valid.
Limitation period – Limit Charging rate limit during the schedule period in Amperes.
Limitation period – Starting from (UTC) Start of the limitation period. The value of StartPeriod also defines the stop time of the previous period.
Remove Remove last schedule period
Add Add another schedule period
Table 28. Fields in the Smart Charging Profile edition
72
GREEN MOTION BUILDING INSTALLATION MANUAL MN191028EN April 2024 www.eaton.com