Troubleshooting
Operating Instructions D888 e-con - 00.0 - 12/2023 207
1061 Error Sewing motor overload /
overvoltage /overcurrent
Check selection of class
Replace the control
Replace motor
Replace encoder
1120 Error Sewing motor initialization
failure
Perform software update
Check selection of class
1121 Error Sewing motor watchdog Perform software update
Check selection of class
1203 Error Position not reached (during
thread cutting, reversal, etc.)
Check the controller settings and change
them if necessary (e.g. thread trimmer
setting, belt tension, etc.)
Check position thread lever at top dead
center
1204 Information Position not reached
(during bartack)
Check the controller settings and change
them if necessary (e.g. thread trimmer
setting, belt tension, etc.)
Check position thread lever at top dead
center
1205 Information Position not reached
(during bartack)
Check the controller settings and change
them if necessary (e.g. thread trimmer
setting, belt tension, etc.)
Check position thread lever at top dead
center
1206 Information Position not reached
(during bartack)
Check the controller settings and change
them if necessary (e.g. thread trimmer
setting, belt tension, etc.)
Check position thread lever at top dead
center
1207 Information Position not reached
(during bartack)
Check the controller settings and change
them if necessary (e.g. thread trimmer
setting, belt tension, etc.)
Check position thread lever at top dead
center