Durkopp Adler D888 handleiding

264 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 150 van 264
Programming Commander DELTA
148 Operating Instructions D888 e-con - 00.0 - 12/2023
5.9.7 Setting the Segment parameters
There are various options for setting the parameters in the seg-
ment. The following table lists all possible options.
Settings that are more complex and therefore require further
explanation are described in more detail after the table.
Icon Parameter Settings
Seam Parameter
Stitch length Value range
01.0 12.0 [mm]
(depending on the sewing
equipment and the subclass)
Needle thread tension Value range
01–99[%]
Sewing foot pressure Value range
01–20
Differentiation Value range
-06 16
Type of differentiation Value range
Top/Bottom
Seam segment length
or
Number of stitches in segment
You can set the active option at
the Technician level Machine
configuration > Seam segment mode.
The s.p.m. option is set at the
factory. The display remains after
the thread has been cut, while
counting/measuring will begin
when sewing starts again.
Max. Speed
It is possible to reduce the maximum
sewing speed at this point. The maximum
sewing speed can be set in the software
at the Technician level.
Value range
0150 2500 [rpm]
(depending on subclass)
Positioning of the needle
Position of the needle when sewing stops.
Value range
On/Off