Programming Commander DELTA
Operating Instructions D888 e-con - 00.0 - 12/2023 147
5.9.6.1 Scan Mode
Before a chip can be read and stored for the first time, you must
select Read & Store.
To check if the chip is the chip that has been stored, you must
select Read & Compare.
Different messages may be displayed during the scan process/
sewing:
Scan required: Please scan the RFID tag.
Scan required: Please scan the same RFID tag again.
Scan again as RFID tags did not match: The Read & Compare
found that the chips did not match. Please scan the same
RFID tag as before.
Another scan required: Please scan the same RFID tag again.
First bartack section
The 1
st
section of the bartack can be
programmed with a different number of
stitches. All subsequent sections have
the preset number of stitches from
the settings for the start bartack.
On/Off
Number of stitches
Value range
01 50 [stitches]
Last bartack section
The last section of the bartack can be
programmed with a different number of
stitches. All previous sections have
the preset number of stitches from
the settings for the start bartack.
On/Off
Number of stitches
Value range
01 50 [stitches]
Invert bartack direction
Normally, a bartack starts either with the
sewing direction (forwards – even number
of sections) or against the sewing direction
(backwards – odd number of sections),
depending on the number of sections.
Setting this parameter inverts the sewing
direction of the bartack.
Value range
On/Off
Icon Parameter Settings