220 Operating Instructions D867 e-con - 00.0 - 06/2023
2187 Error Stepper card X30 transport
interval failure (Stitch length)
• Perform software update
• Check selection of class
2188 Error Stepper card X30 reference
drive failure (Stitch length)
• Check for stiff movement
• Replace encoder
• Replace motor
2201 Error Stepper card X40 reference
drive timeout
• Check reference sensor
2205 Error Stepper card X40 stepper
motor blockage
• Check for stiff movement
2221 Error Stepper card X40 encoder
plug (Sub-D, 9-pin) not
connected
• Connect encoder cable to the control, use
correct connection
2222 Error Stepper card X40 flywheel
position not found
• Check stepper motor 1 for stiff movement
2230 Error Stepper card X40 not
responding
• Perform software update
• Replace the control
2231 Error Stepper card X40 initializa-
tion failure
• Perform software update
• Check selection of class
2252 Error Stepper card X40
overcurrent
• Check for stiff movement
2271 Error Stepper card X40 watchdog
(Foot lifting)
• Perform software update
• Check selection of class
2272 Error Stepper card X40 motor
overload/overvoltage/over-
current (Foot lifting)
• Check selection of class
• Replace the control
• Replace encoder
• Replace stepper motor
2273 Error Stepper card X40 sewing
motor encoder not con-
nected (Foot lifting)
• Replace the control
2274 Error Stepper card X40 sewing
motor encoder not initialized
(Foot lifting)
• Perform software update
• Check selection of class
Code Type Possible cause Corrective