Durkopp Adler D867 e-con handleiding
Handleiding
Je bekijkt pagina 219 van 286

Troubleshooting
Operating Instructions D867 e-con - 00.0 - 06/2023 217
1060 Error Sewing motor overload /
overvoltage /overcurrent
• Check selection of class
• Replace the control
• Replace motor
• Replace encoder
1061 Error Sewing motor overload /
overvoltage /overcurrent
• Check selection of class
• Replace the control
• Replace motor
• Replace encoder
1120 Error Sewing motor initialization
failure
• Perform software update
• Check selection of class
1121 Error Sewing motor watchdog • Perform software update
• Check selection of class
1203 Error Position not reached (during
thread cutting, reversal, etc.)
• Check the controller settings and change
them if necessary (e.g. thread trimmer
setting, belt tension, etc.)
• Check position thread lever at top dead
center
1204 Information Position not reached
(during bartack)
• Check the controller settings and change
them if necessary (e.g. thread trimmer
setting, belt tension, etc.)
• Check position thread lever at top dead
center
1205 Information Position not reached
(during bartack)
• Check the controller settings and change
them if necessary (e.g. thread trimmer
setting, belt tension, etc.)
• Check position thread lever at top dead
center
1206 Information Position not reached
(during bartack)
• Check the controller settings and change
them if necessary (e.g. thread trimmer
setting, belt tension, etc.)
• Check position thread lever at top dead
center
Code Type Possible cause Corrective