Durkopp Adler D867 e-con handleiding
Handleiding
Je bekijkt pagina 218 van 286

Troubleshooting
216 Operating Instructions D867 e-con - 00.0 - 06/2023
1002 Error Sewing motor insulation
error
• Check motor phase and PE for low-
impedance connection
• Replace encoder
• Replace sewing motor
1004 Error Incorrect sewing motor
direction of rotation
• Replace encoder
• Check motor plug assignment and
change it if necessary
• Check wiring in machine distributor and
change it, if necessary
• Measure motor phases and check for
value
1005 Error Motor blocked • Check for stiff movement
• Replace encoder
• Replace sewing motor
1006 Error Maximum speed exceeded • Replace encoder
• Carry out a reset
• Check class (t 51 04)
1007 Error Error in the reference run • Replace encoder
• Check for stiff movement
1008 Error Encoder error • Replace encoder
1010 Error External synchronizer plug
X5T (Sub-D, 9-pin) not
connected
• Connect cable of external synchronizer to
control, make sure that interface (Sync) is
correct
• Only recommended for machines with
transmission!
1011 Error Encoder Z pulse missing • Switch off the control, use handwheel to
turn, and switch on the control again
• If error is not corrected, check encoder
1012 Error Synchronizer fault • Replace synchronizer
1054 Error Internal short circuit • Replace the control
1055 Error Sewing motor overload • Check for stiff movement
• Replace encoder
• Replace sewing motor
Code Type Possible cause Corrective