Troubleshooting
Operating Instructions D867 e-con - 00.0 - 06/2023 215
10 Troubleshooting
10.1 Customer Service
Contact for repairs and issues with the machine:
Dürkopp Adler GmbH
Potsdamer Str. 190
33719 Bielefeld, Germany
Tel. +49 (0) 180 5 383 756
Fax +49 (0) 521 925 2594
Email: service@duerkopp-adler.com
Internet: www.duerkopp-adler.com
10.2 Messages of the software
Code Type Possible cause Corrective
999 Error Error message Software error
1000 Error Sewing motor encoder plug
X5B (Sub-D, 9-pin) not
connected
Connect encoder cable to the control,
use correct connection
1001 Error Sewing motor error
Sewing motor plug X2
(AMP) not connected
Check connection and plug in
Test sewing motor phases (R = 2.8Ω,
high impedance to PE)
Replace encoder
Replace sewing motor
Replace the control