Programming Commander DELTA
Operating Instructions D867 e-con - 00.0 - 06/2023 159
5.10.7.3 Parameters Thread tension sensor mode
Switch-off delay Value range
0 - 9999 [mm]
Seams
Input of the number of signal detections
after which the machine is supposed
to continue with the specifically set
parameters.
Value range
1 - 255
Filter stitches
Loosely woven fabric with stitches may
cause the light barrier to wrongly detect
a signal. To prevent this from happen-
ing, you enter the number of filter
stitches. This number represents the
minimum number of stitches with signal
detection following the 1
st
detection of
the signal.
Value range
0 - 255
Icon Menu item Setting
Lower limit Value range
0000 - 1100
Upper limit Value range
0000 - 1100
Thread tension warning delay
stitches
If the specified maximum of allowed
faulty values is exceeded multiple times
in a row, the software outputs a warning.
Value range
000 - 100
Allowed faulty TT values per
seam
If the specified maximum of allowed
faulty values is exceeded in the entire
seam, the software outputs a warning.
Value range
000 - 100
Icon Menu item Setting