Programming Commander DELTA
158 Operating Instructions D867 e-con - 00.0 - 06/2023
5.10.7.2 Setting the Light barrier parameters
The light barrier detects the beginning and the end of the material.
After a signal was detected, sewing can continue automatically
with the specifically set parameters.
Icon Menu item Setting
Distance
Distance from the detection of the signal
to the end of the material.
The distance signifies the path from the
needle to the light barrier. The path is
specified in millimeters and used by the
machine to independently calculate the
number of stitches.
Value range
0 - 255
Signal detection at seam begin
The signal scan of the light barrier is
performed at the beginning of the seam.
If the function is activated, the light bar-
rier must detect a signal to allow the
machine to sew. If the function is inac-
tive, sewing can take place without sig-
nal detection.
Value range
On/Off
Signal detection at seam end
The signal scan of the light barrier is
performed at the end of the seam. If the
function is active, the machine will con-
tinue to sew with the specifically set
parameters following the signal detec-
tion. If the function is inactive, nothing
will happen.
Value range
On/Off
Start after bartack Value range
On/Off
Start delay Value range
0 - 9999 [mm]