6. Preparation Instructions
– 9 –
6.2 Connection to the Air Supply
(Figs.2 – 3)
Important: ALWAYS disconnect from the air supply
before assembling, carrying out adjustments, servicing
or maintenance.
To connect the air needle scaler to an air line, a 1⁄4" BSP
male thread whip hose
A
will be required.
• Wind a length of PTFE tape
B
around the thread of
the whip hose.
2 Fig.
A
B
• Remove the bung from the air inlet
5
and attach the
hose via the 1 ∕4" BSP air inlet
5
. The connection
must be tight for an airtight union.
3 Fig.
A
5
6.3 Attaching the Scaling Head (Fig.4)
• Screw the head
2
clockwise onto the threaded
cylinder of the tool body.
4 Fig.
2