5.9 Generator Port Use Setup Menu
Generator input rated power: allowed Max. power from diesel
generator.
GEN connect to grid input: connect the diesel generator to the
grid input port.
Smart Load Output: Use the GEN port as an AC output port, and
the load connected to this port can be controlled on/off by the
hybrid inverter.
e.g. ON: 100%, OFF: 95%: When the battery bank SOC reaches
100%, Smart Load Port will switch on automatically and power
the load connected. When the battery bank SOC < 95% , the
Smart Load Port will switch off automatically.
Mode
OFF
ON
Generator Input
SmartLoad Output
Micro Inv Input
On Grid always on
GEN connect to Grid input
Ml export to Grid cutoff
GEN PORT USE
55.00Hz
154.0V
151.0V
Rated Power
AC Couple Frz High
8000W
PORT
Set1
Mode
OFF
ON
Generator Input
SmartLoad Output
Micro Inv Input
On Grid always on
GEN connect to Grid input
Ml export to Grid cutoff
GEN PORT USE
55.00Hz
100%
95%
Rated Power
AC Couple Frz High
8000W
PORT
Set1
Mode
OFF
ON
Generator Input
SmartLoad Output
Micro Inv Input
On Grid always on
GEN connect to Grid input
Ml export to Grid cutoff
GEN PORT USE
55.00Hz
90%
100%
Rated Power
AC Couple Frz High
8000W
PORT
Set1
Smart Load OFF Batt
• Battery SOC or voltage at which the Smart load will switch off.
Smart Load ON Batt
• Battery SOC or voltage at which the Smart load will switch on.
On Grid always on: When "on Grid always on" is checked, the
smart load port will always keep switching on if hybrid inverter is
operating in on-grid mode.
Micro Inv Input: Use the GEN port as an AC couple input port,
which can be connected with micro-inverter or other Grid-Tied
inverter.
*Micro Inv Input OFF: When the battery SOC or voltage rise to
this set value and the hybrid inverter is operating in off-grid mode,
the frequency of GEN port of hybrid inverter will be raised to 'AC
Couple Frz High' to trip the Grid-tied inverter. It's invalid in on-grid
mode.
*Micro Inv Input ON: When the battery SOC or voltage drops
below this set value, the relay on GEN port of hybrid inverter will
be switched on, then the Grid-Tied inverter will generate power
and feed into hybrid inverter.
AC Couple Frz High: If choosing"Micro Inv input", as the battery
SOC reaches gradually setting value (OFF), during the process, the
microinverter output power will decrease linear. When the battery
SOC equals to the setting value (OFF), the system frequency will
become the setting value (AC couple Frz high) and the Microinvert-
er will stop working.
Ml export to Grid cutoff: Stop exporting power produced by the
microinverter or Grid-Tied inverter to the grid.
*Note: Micro Inv Input OFF and On is valid for some certain FW
version only.