2121
Apertura fascetta
(vedere tabelle iniettori)
Q P
Fig. 2.8
Ring opening
[mm]
REGULATION OF AIR SUPPLY TO
OVEN BURNER
Using a cross-head screwdriver, slacken the screw
Qsecuring the air ow regulation collar P(g. 2.8)
and turn the collar forward or backward to increase or
reduce the air aperture in accordance with gas type
and the indications in the ‘Table for the choice of the
injectors’.
Light the burner and check the ames.
ADJUSTMENT OF THE OVEN
BURNER MINIMUM
Considering that in the minimum position the ame
must have a length of about 4 mm and must remain
lit even with a brusque passage from the maximum
position to that of minimum.
The ame adjustment is done in the following way:
turn on the burner by setting the thermostat knob
on position Max
(maximum);
remove the knob and unscrew the by-pass screw
G” (g. 2.9) about three times by passing a small
at screwdriver 3 mm blade, 100 mm length)
through the panel opening;
re-mount the knob and let the oven heat up for
about 10 minutes, then bring the knob to position
130 (minimum) to operate the thermostat bypass;
after having removed the knob again and being
very careful not to turn the tap rod, slowly screw
the by-pass screws “G(g. 2.9) until you obtain a
ame of 3-4 mm in height.
N.B. For G30/G31 (LPG) the by-pass screw must be
xed thoroughly.
Fig. 2.9
G