2222
Flame correct
Flame faulty in
primary air
Flame with exces s
primary air
Flame faulty
in primary
air
Flame
correct
Flame with
excess
primary air
long, yellow
and trembling
clear interior
blue cone
short and sharp
too blue interior
cone tending to
detach
CAUSE
air regulating
tube, too
closed
correct
distance of
the tube
air regulating
tube, too
open
FOR YOUR SAFETY PLEASE READ THE FOLLOWING INFORMATION:
This appliance must be installed by a qualied technician according with the current local regulations and in
compliance with the manufacturer instructions.
This appliance is supplied with a moulded 13 amp three pin mains plug with a 13 amp fuse tted. Should the fuse
require replacement, it must be replaced with a fuse rated at 13 amp and approved by ASTA or BSI to BS 1362.
The plug contains a removable fuse cover that must be retted when the fuse is replaced. In the event of the fuse
cover being lost or damaged, the plug must not be used until a replacement cover has been obtained. Replacement
fuse covers can be purchased from your nearest electrical dealer and must be the sarne colour as the original.
IF THE MOULDED MAINS PLUG IS UNSUITABLE FOR THE SOCKET OUTLET IN YOUR HOME OR IS REMOVED
FOR ANY OTHER REASON, THEN THE FUSE SHOULD BE REMOVED AND THE CUT OFF PLUG DISPOSED OF
SAFELY TO PREVENT THE HAZARD OF ELECTRIC SHOCK.
THERE IS A DANGER OF ELECTRICAL SHOCK IF THE CUT OFF PLUG IS INSERTED INTO ANY 13 AMP
SOCKET OUTLET.
If a replacement plug is to be tted, please observe the wiring
code shown below.
Warning! This appliance must be earthed.
A properly earthed three pin plug (fused at 13 amps, to BS 1362
ASTA approved) must be used. As the colours of the wires in the
mains lead of this appliance may not correspond with the coloured
markings identifying the terminals in your plug, proceed as follows:
The wire which is coloured GREEN & YELLOW
must be connected to the terminal in the plug which
is marked with letter “E” or by the Earth symbol
” or coloured GREEN & YELLOW.
The wire which is coloured BLUE must be connected to
the terminal which is marked with the letter “N” or coloured
BLACK.
The wire which is coloured BROWN must be connected to
the terminal which is marked with the letter “L” or coloured
RED.
IMPORTANT: The cooker must be installed in accordance with the manufacturer’s instructions. Incorrect
installation, for which the manufacturer accepts no responsibility, may cause damage to persons, animals
and things.
The connection of the appliance to earth is mandatory. The manufacturer declines all responsability for any
inconvenience resulting from the inobservance of this condition.
Before e󰀨ecting any intervention on the electrical parts of the appliance, the connection to the network
must be interrupted.
Green & Yellow
Earth
3 amp fuse
Blue Neutral
Brown Live
Fig. 3.1