Part Number: 9291458 11/17 21
Section 2 Installation
6. The 1” diameter drain on N8100-FA models is shipped
loose and must be connected during installation.
N8157-FA, N8169-FA and N8182-FA have two 1” drains.
A. Provided 1” (25mm) drain, nut and washer must
be field installed to an appropriate container or
floor drain following local code requirements.
Sinks come standard with 1-1/2” basket strainer
assemblies.
B. Remove/drill foam out of drain hole.
C. Apply thin ring of plumbers putty around the
drain.
D. From the inside drop the drain into the drain hole.
E. From the outside secure the drain with the washer
and nut.
F. Tighten the nut with channel locks, use a fork to
hold the drain in place if necessary.
G. Clean up excess plumbers putty.
7. Construct an air duct (not provided) connecting
the condenser face to the louver. This will prevent
recirculation of discharge air.
11.00”
(28cm)
Counter Cutout Dimensions
22.0” (56cm)
8.00”
(20cm)
11.00” (28cm)
Air duct dimensions
to match condenser face
Are Model Specic
8. Inside the well, the fan assembly has standoff brackets
with tabs. The tabs should be bent up.
9. Place the coil assembly cover slots over the bracket
tabs. This will secure the cover is in the correct location
and will not disrupt the air flow.
10. The upright air diffuser will only fit one way on the
drain side.
Upright Air Diuser
With Air Deector
Black Airow Extrusions
Perforated Pan Clip
Adapter Bars
Coil Assembly Cover
Plexiglas
End Caps