Delfield N8046N handleiding

40 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 21 van 40
Part Number: 9291458 11/17 21
Section 2 Installation
6. The 1” diameter drain on N8100-FA models is shipped
loose and must be connected during installation.
N8157-FA, N8169-FA and N8182-FA have two 1” drains.
A. Provided 1” (25mm) drain, nut and washer must
be field installed to an appropriate container or
floor drain following local code requirements.
Sinks come standard with 1-1/2” basket strainer
assemblies.
B. Remove/drill foam out of drain hole.
C. Apply thin ring of plumbers putty around the
drain.
D. From the inside drop the drain into the drain hole.
E. From the outside secure the drain with the washer
and nut.
F. Tighten the nut with channel locks, use a fork to
hold the drain in place if necessary.
G. Clean up excess plumbers putty.
7. Construct an air duct (not provided) connecting
the condenser face to the louver. This will prevent
recirculation of discharge air.
11.00”
(28cm)
Counter Cutout Dimensions
22.0” (56cm)
8.00”
(20cm)
11.00” (28cm)
Air duct dimensions
to match condenser face
Are Model Specic
8. Inside the well, the fan assembly has standoff brackets
with tabs. The tabs should be bent up.
9. Place the coil assembly cover slots over the bracket
tabs. This will secure the cover is in the correct location
and will not disrupt the air flow.
10. The upright air diffuser will only fit one way on the
drain side.
Upright Air Diuser
With Air Deector
Black Airow Extrusions
Perforated Pan Clip
Adapter Bars
Coil Assembly Cover
Plexiglas
End Caps

Bekijk gratis de handleiding van Delfield N8046N, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkDelfield
ModelN8046N
CategorieKoelkast
TaalNederlands
Grootte5826 MB