Delfield CAB2-813 handleiding

28 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 23 van 28
Part Number: 9291468 09/17 23
Section 4 Maintenance
CT Series Self-Leveling Dispensers Adjusting
Tools Needed:
Small flat head screw driver
Phillips head screw driver
n
Warning
Wear safety glasses when adjusting your dispenser.
Also, lock brakes on mobile units before beginning.
1. Unload dispenser.
2. Use screw driver to remove two screws, one on each
side of the elevator housing.
3. Remove cover and slide front panel off.
4. If carrier is riding too high, you need to remove springs.
With carrier all the way to the top, gently disengage
one spring at a time, unhooking bottom loop out of
carrier bracket. Remove as many springs as necessary.
If carrier is riding too low, you need to add springs. With
carrier all the way to the top, gently engage one spring
at a time by hooking bottom loop of spring into carrier
bracket. Add as many springs as necessary.
5. Load unit to test dispensing level. If spring adjustment
does not position carrier properly, repeat step #4 trying
different springs. If this does not work, a different set of
springs may be required.
6. If level is appropriate, replace front panel and cover.
Secure with screws.
,
Caution
Dispenser should not be operated with front panel off
elevator housing.

Bekijk gratis de handleiding van Delfield CAB2-813, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.