DATEQ SPL6 configuration manual Configuration
25
Logging
The SPL6 records all measured values into PDF and CSV file format. An
independent file is generated for each day. Select the values that need to be
implemented. By default all values are available.
Data not selected for the file reports
stays available within the SPL6.
Exception on the storage are the
overload sound samples. These are local
privacy regulation dependent.
The SPL6 stores measured values for
each second. This way an historic record
can be viewed at each point in time.
Reports are generated on the selected interval day or weekly.
The reports are send out by FTP or email to an external server.
Contact your local network administrator for the server details.
After setting the server details the SPL6 will send out all day
reports. These reports contain all selected information from the
past full day or days.
When no connection to the servers can be made an error
message will be stored. The SPL6 will not try to resend but add
the not send reports to next planned.