Configuration DATEQ SPL6 Configuration manual
UK
Display
The front panel display allows to view different values.
Large:
• dB(A) (standard)
• dB(C)
• Leq-1
• Leq-2
• dB peak
Small:
• dB(A)
• dB(C) (standard)
• Leq-1
• Leq-2
• dB Peak
Leq:
Leq:
• Leq-1 (standard)
• Leq-2
The bottom VU meter always shows fast VU.
Integrated fast VU: 0.125 seconds, Integrated slow VU: 1 second.
History screen: 2 till 60 minutes, standard 2 minutes. Screen divided into 120 markers.
Leq value 1:
Maximum: 50 tot 125dB, standard 85
Leq filter: A of C, standard A
Leq calculation: 1 tot 360 seconds and 1 tot 60 minutes, standard 2
minutes.
Enable: standard on
Leq value 2:
Maximum: 50 tot 125dB, standard 85
Leq filter: A of C, standard C
Leq calculation: 1 tot 360 seconds en 1 tot 60 minutes, standard 15 minutes
Enable: standard off
Leq-1 en 2 automatically change name in all views to the selected time and filter weight.
For example: Laeq2m or Lceq15m.
External Display:
Type: Off, SPL-D2 MK2, standard SPL-D2 MK2
Show: dB(A), dB(C), dB, Leq-1, Leq-2, standard dB(A)
Bar: fast VU, slow VU, reduction, standard fast VU.
SPL-D2 optional external display: